Mounting instructions, Wiring harness – SARGENT 4292 Keypads User Manual
Page 3
02/10/11
1-800-810-WIRE • www.sargentlock.com •
A6851J 3
Copyright © 2011, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
4291 and 4292 Keypads
Mounting Instructions
A. Important
CAUTION:
Disconnect all power before beginning
installation to prevent electrical shock and
equipment damage.
1. Installer must be a trained, experienced
service person.
2. All wiring must comply with applicable local
electrical codes, ordinances and regulations.
B. Installation
1. Mount outlet box to stud or other rigid structure.
Use Outlet Box Slater S1-18W for indoor
applications and Waxman 35-276 for outdoor
applications (not furnished).
2. Install and wire electric locking devices, monitor-
ing components and power sources to appropri-
ate keypad connections.
3. Figure A shows color code wiring connections
on keypad.
4. Figure B (pg.3) shows typical wiring when
using SARGENT’s electrical locking devices
with accessories.
5. Fasten wallplate with keypad to outlet box using
machine screw furnished. See Figure C for 4292
keypad outdoor installations.
6. Energize power supply and refer to Programming
Procedures (pg. 5)
4
Warning:
Plug this harness in on the proper pins.
Permanent damage will result if incorrectly inserted.
White
Wht/blue
Wht/red
Orange
Brown
Wht/orange
Wht/black
Wht/yellow
Black
Red
10
9
8
7
6
5
4
3
2
1
Note:
LED’s shown are for the 4291 keypad.
LED’s for 4292 are located on the front right side.
Wiring Harness
Not used
Aux 2 Output
(SINK 50mA)
Aux 1 Output
(SINK 50mA)
Panic Output
(SINK 50mA)
Request to Exit
Input
Request Input
Common
Keypad Active
(SINK 50mA)
N/A
Output Ground (Only)
24 +
Fig. A