Transmig vaf4hd – Tweco VAF4HD Transmig User Manual
Page 63

TRANSMIG VAF4HD
Manual 0-5269
4-3 SERVICE
Error Code
Description
Cause
Remedy
Left
Display
Right
Display
ERR
05--
Feedback signal of
motor lost
Tachometer feedback wiring
between Wirefeeder motor
and motor control PCB not
connected or motor is stalled.
Disconnect Wirefeeder from Power
Source. Check wiring between
Wirefeeder motor Tachometer and
motor control PCB is correctly
connected. Reconnect Wirefeeder to
Power Source and if ERR 05 appears
again with the next weld then
contact your Accredited CIGWELD
Service Provider to investigate the
fault.
ERR
06--
Output current of
Wirefeeder exceeds
allowed maximum
value limit
1. Current running through
Wirefeeder exceeds 650A for 4
minutes.
2. Welding current signal from
Power Source is too high
with respect the actual weld
current.
1. Turn OFF Wirefeeder and allow it
to cool for 10 minutes then reduce
voltage / wirespeed setting to reduce
welding current below 650A@40%.
2. Contact your Accredited
CIGWELD Service Provider to
investigate the fault.
ERR
07--
Power Source Arc
Established signal
has not been received
within 20 seconds of
commencing welding
Power Source does not provide
an Arc Establish signal.
Override the Arc Established signal,
refer to Subsection 3.24 or retrigger
the wirefeeder.
ERR
08--
Main control PCB
settings save or read
error
Motor Control PCB Memory IC
read/write cycle limit has been
exceeded.
1. Turn Wirefeeder OFF then ON and
check to see if settings can then be
saved.
2. Contact your Accredited
CIGWELD Service Provider to
investigate the fault.
ERR
20--
Display PCB settings
save or read error
Display PCB Memory IC read/
write cycle limit has been
exceeded.
1. Turn Wirefeeder OFF then ON and
check to see if settings can then be
saved.
2. Contact your Accredited
CIGWELD Service Provider to
investigate the fault.
ERR
21--
Welder mode
undefined
Incorrect DIP switch setting.
Disconnect Wirefeeder from Power
Source then check DIP switch
setting and set S3S4S5 DIP switch
as to Subsection 3.09.
ERR
22--
Wirefeeder mode
undefined
Incorrect DIP switch setting.
Disconnect Wirefeeder from Power
Source then check DIP switch
setting and set S1S2 DIP switch as
to Subsection 3.09.
Table 4-1 Error Codes and Remedies
NOTE
Once cause of error has been corrected then the power to the Wirefeeder must be turned OFF then ON
to reset and clear Error Code from the display.
Please follow Subsection 4.08 for more information regarding troubleshooting.