Transmig vaf4hd – Tweco VAF4HD Transmig User Manual
Page 25

TRANSMIG VAF4HD
Manual 0-5269
3-7
INSTALLATION, OPERATION AND SETUP
15. 8 Pin Remote Control Socket
The 8 pin Remote Control Socket is used to connect remote control devices to the welding power source. To make
connections, align keyway, insert plug, and rotate threaded collar fully clockwise.
2
1
8
7
6
3
4
5
Trigger Switch
Remote Volts in
GMAW Mode
1
2
3
4
5
6
7
8
W
V
Remote Wirespeed in GMAW mode
Figure 3-2 8 Pin Remote Control Socket
Socket Pin
Function
1
Not connected
2
Trigger Switch Input
3
Trigger Switch Input
4
Not connected
5
5k ohm (maximum) connection to 5k ohm remote control potentiometer.
6
Zero ohm (minimum) connection to 5k ohm remote control potentiometer.
7
Wiper arm connection to 5k ohm remote control Wirespeed MIG mode potentiometer.
8
Wiper arm connection to 5k ohm remote control Volts MIG mode potentiometer.
Table 3-1 Pin Function in 8 Pin Remote Control Socket
NOTE
The remote/ local setting in Advanced Features Menu should be set to remote for the remote wire feeder
amperage/voltage controls to be operative.
16. 4 Pin Trigger Socket
The 4 pin Trigger Socket is used to connect remote control devices to the welding power source. To make con-
nections, align keyway, insert plug, and rotate threaded collar fully clockwise.
1
2
3
4
1
2
3
4
Trigger Switch
Figure 3-3 4 Pin Trigger Socket
Socket Pin
Function
1
Trigger Switch Input
2
Trigger Switch Input
3
Not connected
4
Not connected