Tweco WC 1 Weld Sequence Controlle User Manual
Page 25

21
COMMAND
PARAMETER DESCRIPTION
RANGE
W1
Weld Schedule Mode Flag:
Bit 0 – Enable Pulse Weld Mode
Bit 1..7 – Not defined
0-255
W2
Active Weld Schedule number
1-32
W3
Active Weld Event number
0 -
Cycle Off
1 -
Cycle Start
2 -
Pre Purge
3 -
Start Time
4 -
Ramp Up Time
5 -
Run Time (Spot Weld Time if enabled)
6 -
Taper Current time
7 -
Ramp Down Time
8 -
End Time
9 -
Wire Reverse Time
10 -
Burn Back Time
11 -
Post Purge Time
0-11
W4
Write current schedule to specified weld schedule number
1-32
W5
Read specified weld schedule from memory to active schedule
1-32
Table 9 - Weld Mode Command Table
COMMAND
PARAMETER DESCRIPTION
RANGE
A1
Minimum Power supply current output (A1 = AMP
min
) used for DAC 1
scaling.
0-255
A2
Maximum Power supply current (A2=AMP
max
) used for DAC 1 scaling
Where: (DAC 1 Gain = [4000/( AMP
max
– AMP
min
)])
0-500
A3
Minimum Wire Feed speed (A3 = WIRE
min
) used for DAC 2 scaling
0-255
A4
Maximum Wire Feed Speed (A5=WIRE
max
) used for DAC 2 scaling
Where: (DAC 2 Gain = [4000/( Wire
max
– WIRE
min
)])
0-900
A5
Actual Setpoint value for DAC 1
0-500
A6
Actual Set point value for DAC2
0-900
Table 10 - Analog Scaling Command Table