19

7.3 Terminal Commands

The following is a summary of the Terminal Commands supported by the WC 1:

COMMAND

PARAMETER DESCRIPTION

RANGE

UNITS

V1

Prepurge time

0-650.00

.01Sec.

V2

Arc start current

0-500

Amps

V3

Arc Start Wire feed speed

0-650

Ipm

V4

Arc Start delay time

0-650.00

.01 Sec.

V5

Ramp up Delay time

0-650.00

.01 Sec

V6

Run time current (Pulse Peak current)

0-650.00

Amps

V7

Run Time wire feed speed

0-650

Ipm

V8

Spot Weld Time (If Time=0 then Manual control)

0-650.00

.01 Sec.

V9

Percent Taper current

0-100

%

V10

Taper current delay time

0-650.00

.01 Sec.

V11

Ramp down delay time

0-650.00

.01 Sec.

V12

End current value

0-500

Amps

V13

End wire feed speed

0-650

Ipm

V14

End delay time

0-650.00

.01 Sec.

V15

Reverse wire speed time delay

0-650.00

Sec.

V16

Wire burn back delay time

0-650.00

.01 Sec.

V17

Post gas flow time delay

0-650.00

.01 Sec.

V18

Pulse current on time

.001 – 65.000

.001 Sec.

V19

Pulse current off time

.001 – 65.000

.001 Sec.

V20

Percent back ground current

0-100

%

V21

Jog wire feed speed

0-650

Ipm

Table 7 - Weld Process and Command Table