beautypg.com

Auto-cut 300 xt – Tweco 300 XT Auto-Cut 400V User Manual

Page 95

background image

AUTO-CUT 300 XT

Manual 0-5290

APPENDIX

A-13

CCM I/O PCB

Test Points

TP1

GND

TP2

/COOLANT FANS ON

TP3

/TORCH PUMP ON

TP4

LOW COOLANT FLOW (SW)

TP5

COOLANT FLOW SIGNAL (PULSE)

TP6

+15V ISOLATED

TP7

-15V ISOLATED

TP8

+18V ISOLATED

TP9

ANALOG CURRENT CONTROL 0-3.3V

TP10

GND ISOLATED

TP11

/PILOT ENABLE

TP12

+5VDC

TP13

-15VDC

TP14

+15VDC

TP15

24VDC

TP18

+5V ISOLATED

TP19

WORK CURRENT

LED Reference

D2

Green PLASMA ENABLE

D3

Green E-STOP_PS

D4

Green GAS ON

D6

Green CNC START

D8

Green HOLD START

D12

Green PREFLOW ON

D13

Green CSD

D18

Green MARK

D20

Green SPARE1

D25

Green EXP METAL

D33

Green OK TO MOVE

D37

Green PSR

D41

Green SPARE FIELD OUT 2

D43

Green SPARE FIELD OUT 1

J Connectors

J21

BASIC CNC

J22

EXTENDED CNC

J23

RELAY - INTERFACE BOARD

J24

ARC / TIP VOLTS

J25

TEST

J26

GAS BOX

J28

TO CPU

J29

TO CPU