AUTO-CUT 300 XT

Manual 0-5290

APPENDIX

A-37

section (INV 1A, INV 1B, etc.). A 100A unit will only have ribbon cables in J31 & J32; a 200A will have J31-J33 filled

with the others empty. 300A will have J34 missing with the others filled.

Other boards in the system include the System Bias Supply, the Relay & Interface PCB, Display PCB, Pilot PCB

and AC Suppression PCB.

The CCM has 2 boards, the I/O (input/output) and the CPU (central processing unit)

board. The CE units will also have one or more EMI Filter boards on the input power.

System Bias supply PCB

is powered from the 3 phase AC input and works from about 150V to over 600V covering

all the normal voltage ranges. It can operate from 2 phases (single phase) so it still provides bias power and can

report a fault if a phase is missing. The supply’s output is 24 VDC which powers the Relay board, the Display, the

Pilot board and the 2 boards in the CCM. System Bias also contains circuits to detect missing phase and determine

if the AC voltage is within the correct range, not too high or too low. It also signals to the CCM what voltage the

unit is configured for. The System Bias supply PCB includes a relay, K1, which only applies voltage to Auxiliary

transformer, T1, primary when the input voltage is in the correct range.

The Relay and Interface PCB Accepts and distributed the output of the Aux Transformer. It has relay to control

the pump, fans, input contactors, the Arc Starter and the Inrush relays. A circuit on the Relay board accepts input

from the Work current sensor, HCT1, and Pilot current sensor (on the Pilot PCB) and sends the Enable signal to

the Pilot boards IGBT switches via the J3 to J42 ribbon cable. Other inputs on the Relay board include those from

the Negative Temperature Coefficient (NTC) ambient and coolant temperature sensors. Coolant tank level switch

and coolant flow switch, which determines if the flow is above the required minimum rate, also send signals to the

Relay Board. Ultra-Cut units include a flow sensor whose output to the Relay Board is a series of pulses whose

frequency indicates the flow rate and can detect the presence of gas bubbles in the coolant. All these signals pass

to the CCM via a 40 conductor ribbon cable going to the CCM I/O board.

The Display Board Has LEDs for AC, TEMP, GAS & DC. It also has a 4 digit 7 segment display for status and fault

information. AC LED indicates the input contactors to the inverters have been commanded to close, but does not

mean they are closed. TEMP means one or more inverters or the coolant has exceeded the allowed temperature.

GAS means gas is flowing and coolant flow is OK. DC means the inverters output voltage is above 60 VDC.

The first digit of the 7 segment display shows the letter, “C”; “E”; “L” or is blank. During the initial power up se-

quence the letter “C” followed by the other 3 digits, indicates the CCM code revision. Status or Fault codes which

may occur during the power up sequence or any time thereafter are preceded by letters “E” for an active fault or

“L” for a “latched” or “last” fault that stopped the process but is no longer active. When there is no Fault or active

Status code, the output current setting is displayed with the first digit blank. If the system is an Ultra-Cut XT using

the Auto Gas Control, DFC 3000, the display will show “0” until a process has been loaded. If there is a fault or

other status showing the display will alternate between the current setting and the fault.

The Pilot PCB contains a pair of parallel IGBT transistors working as an electronic switch to connect and disconnect

the torch tip from the 1st inverter section.

When the pilot electronic switch is closed and the pilot is ignited by the Arc Starter, current from the 1st section

flows between electrode and tip. Then as transfer begins, a small current from the 2nd inverter flows from elec-

trode to work. When transfer is detected the pilot switch is opened and current from the 1st section is free to flow

to the work through the diode which is also on the Pilot board. The Pilot PCB also contains a pilot current sensor

to detect and measure the level of pilot current. Additional resistor/capacitor (RC) circuits on the pilot PCB assist

and stabilize the pilot and transferred arcs.