AUTO-CUT 300 XT
2-2
SPECIFICATIONS
Manual 0-5290
2.05 Power Supply Specifications & Electrical Requirements
300 Amp System
Auto-Cut 300 XT™ Specifications & Design Features
Max OCV (U0)
425 vdc
Minimum Output Current
5 Amps
Max Output Current
300 Amps
Output Voltage
60 - 180 vdc
Duty Cycle Rating
100% @ 300A, 200V, (60kW),
Ambient Temperature
for Duty Cycle Rating
104F° (40°C)
Operating range
14°F to 122°F (-10°C to + 50°C)
Power Factor
0.93 @ 300 A DC Output
Cooling
Coolant and Forced Air (Class F)
Auto-Cut 300 XT™ Power Supply
Input
Power Input
Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps) Wire (AWG) Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
3-Ph
380
50/60
63
97
150
#4
25
IEC
380
50/60
71
110
150
#4
25
NOTE
* Suggested wire size based on United States NFPA 70 National Electrical Code 2011 edition published by the
National Fire Prevention Association. Listings are from table 400.5(A)(2) for flexible cord of certain types rated
for 75 deg C in ambient temperatures up to 30 deg C. Using wires of lower temperature rating or different insu-
lation type may require larger wire size. Derate for higher ambient.
These are suggestions only. Always refer to your local and national codes that apply to your region for final