2-2

SPECIFICATIONS

Manual 0-5290

2.05 Power Supply Specifications & Electrical Requirements

300 Amp System

Auto-Cut 300 XT™ Specifications & Design Features

Max OCV (U0)

425 vdc

Minimum Output Current

5 Amps

Max Output Current

300 Amps

Output Voltage

60 - 180 vdc

Duty Cycle Rating

100% @ 300A, 200V, (60kW),

Ambient Temperature

for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.93 @ 300 A DC Output

Cooling

Coolant and Forced Air (Class F)

Auto-Cut 300 XT™ Power Supply

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps) Wire (AWG) Wire (mm

2

)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

3-Ph

380

50/60

63

97

150

#4

25

IEC

380

50/60

71

110

150

#4

25

NOTE

* Suggested wire size based on United States NFPA 70 National Electrical Code 2011 edition published by the
National Fire Prevention Association. Listings are from table 400.5(A)(2) for flexible cord of certain types rated
for 75 deg C in ambient temperatures up to 30 deg C. Using wires of lower temperature rating or different insu-
lation type may require larger wire size. Derate for higher ambient.
These are suggestions only. Always refer to your local and national codes that apply to your region for final
determination of correct wire type and size.