Cutmaster a40, a60, 01 front panel controls / features – Tweco A40-A60 CutMaster User Manual
Page 31
CUTMASTER A40, A60
Manual 0-5120
OPERATION
4-1
SECTION 4 SYSTEM:
OPERATION
4.01 Front Panel Controls / Features
See Illustration for numbering Identification
1. Output Current Control
Sets the desired output current. Output settings
up to 60 Amps may be used for drag cutting, when
hand torch is used and the torch tip contacting
the workpiece or higher for standoff cutting. For
automation current control settings greater than
45 Amps will stop the arc and remove the “OK to
Move” signal when the tip contacts the plate. For
currents below 45 Amps the cutting will continue
even when the tip is in contact with the work.
2. Function Control
Function Control Knob, Used to select between
the different operating modes.
SET
Used to purge the air through the unit
and torch and leads and to adjust gas pressure.
RUN
Used for general cutting operations
RAPID AUTO RESTART
Allows for faster
restarting of the Pilot Arc for uninterrupted cutting.
LATCH
Used for longer hand held
cuts. This feature is disabled while the automation
torch is used, and is enabled when a hand torch is
connected. Once a cutting arc is established, the
torch switch can be released. The cutting arc will
remain on until the torch is lifted away from the
work piece, the torch leaves the edge of the work
piece the torch switch is activated again or if one
of the system interlocks is activated.
3. On Off Power Switch
ON / OFF
Switch controls input power to
the power supply. Up is ON, down is OFF.
4. Air/Gas Pressure Control
The Pressure
+
Control is used in the
"SET" mode to adjust the air/gas pressure. Pull
the knob out to adjust and push in to lock.
5.
AC Indicator
Steady light indicates power supply is ready
for operation. Blinking light indicates unit is in
protective interlock mode. Shut unit off, shut off
or disconnect input power, correct the fault, and
restart the unit. Refer to Section 5 for details.
A
+
PSI
BAR
MAX
MAX
MIN
MIN
!
1
2
3
4
5 6 7 8 9
Art# A-07886
MIN
MAX
10
6.
Temp Indicator
Indicator is normally OFF. Indicator is ON when
internal temperature exceeds normal limits. Let
the unit cool before continuing operation.
7.
Gas Indicator
Indicator is ON when minimum input gas pres-
sure for power supply operation is present. Mini-
mum pressure for power supply operation is not
sufficient for torch operation.
8.
DC Indicator
Indicator is ON when DC output circuit is active.
9.
!
Fault Error Indicator
Indicator is ON when Fault circuit is active. See
section 5 for explanations of fault lights.
10. Pressure Indicators
PSI
BAR
MAX
MAX
MIN
MIN
80
75
70
65
5.5
85
5.9
90
6.3
5.2
4.8
4.5
Art # A-08170
The Indicators will illuminate according to the
pressure set by the Pressure Control Knob (num-
ber 4).