Schedule menu – tekmar 654 Snow Melting Control Installation User Manual
Page 16

©
2013 654_D
-
06/13
16
of
44
Schedule Menu
The Schedule menu can operate on a 24 hour or 7 day repeating schedule. When a 24 hour schedule is selected,
“SuMoTuWeThFrSa” is shown on the top of the screen to show that the event time applies to all days of the week. When
a 7 day schedule is selected, each individual day of the week is shown with the event time.
The Schedule menu is not available when the Application Mode is set to 090.
Item Field
Range
Access
Description
Set to
SuMoTuWeThFrSa
12:00 AM to 11:50
PM, SKIP
or
00:00 to 23:50,
SKIP
Default = 6:00 AM
User
Installer
EVENT 1
The first programmable schedule time period of the
day. During Event 1 the control operates in MELT
operation.
SuMoTuWeThFrSa
12:00 AM to 11:50
PM, SKIP
or
00:00 to 23:50,
SKIP
Default =
10:00 PM when
Event/Day is 2
8:00AM when
Event/Day is 4
User
Installer
EVENT 2
The first programmable schedule time period of the
day. During Event 2 the control operates in OFF or
IDLE operation.
SuMoTuWeThFrSa
12:00 AM to 11:50
PM, SKIP
or
00:00 to 23:50,
SKIP
Default = 6:00 PM
User
Installer
EVENT 3
The first programmable schedule time period of the
day. During Event 3 the control operates in MELT
operation.
SuMoTuWeThFrSa
12:00 AM to 11:50
PM, SKIP
or
00:00 to 23:50,
SKIP
Default = 10:00
PM
User
Installer
EVENT 4
The first programmable schedule time period of the
day. During Event 4 the control operates in OFF or
IDLE operation.
Always available
OFF, ZONE
Available with
tekmarNet
®
OFF, ZONE,
Master 1, 2, 3, 4,
Member 1, 2, 3, 4
Default = OFF
User
Installer
SCHEDULE
Select if the control should change the temperature
automatically using a programmable schedule.
OFF = Programmable schedule is not used.
Zone = Applies to this control only.
Master 1, 2, 3, 4 = In charge of one of four available
network schedules.
Member 1, 2, 3, 4 = Follows selected network
schedule.
2 or 4
Default = 2
User
Installer
EVENT PER DAY
Select the number of temperatures per day.
24 hour or 7 day
Default = 24 hour
User
Installer
24 HOUR / 7 DAY
Select between a 24 hour schedule or a 7 days per
week schedule.