beautypg.com

Maximum ratings, Operating range, Dc electrical characteristics – Cypress CY7C1312AV18 User Manual

Page 9: Ac electrical characteristics

background image

CY7C1310AV18

CY7C1312AV18

CY7C1314AV18

PRELIMINARY

Document #: 38-05497 Rev. *A

Page 9 of 21

Maximum Ratings

(Above which useful life may be impaired.)
Storage Temperature .................................–65°C to +150°C
Ambient Temperature with

Power Applied.............................................–55°C to +125°C
Supply Voltage on V

DD

Relative to GND........ –0.5V to +2.9V

DC Voltage Applied to Outputs

in High-Z State .................................... –0.5V to V

DDQ

+ 0.5V

DC Input Voltage

[12]

............................ –0.5V to V

DDQ

+ 0.5V

Current into Outputs (LOW)......................................... 20 mA
Static Discharge Voltage.......................................... > 2001V

(per MIL-STD-883, Method 3015)
Latch-up Current.................................................... > 200 mA

Operating Range

Range

Ambient

Temperature(T

A

)

V

DD

[14]

V

DDQ

[14]

Com’l

0°C to +70°C

1.8

± 0.1 V

1.4V to V

DD

DC Electrical Characteristics

Over the Operating Range

[9,14]

Parameter

Description

Test Conditions

Min.

Typ.

Max.

Unit

V

DD

Power Supply Voltage

1.7

1.8

1.9

V

V

DDQ

I/O Supply Voltage

1.4

1.5

V

DD

V

V

OH

Output HIGH Voltage

[10]

V

DDQ

/2 –0.12

V

DDQ

/2 + 0.12

V

V

OL

Output LOW Voltage

[11]

V

DDQ

/2 – 0.12

V

DDQ

/2 + 0.12

V

V

OH(LOW)

Output HIGH Voltage

I

OH

=

−0.1 mA, Nominal Impedance

V

DDQ

– 0.2

V

DDQ

V

V

OL(LOW)

Output LOW Voltage

I

OL

= 0.1 mA, Nominal Impedance

V

SS

0.2

V

V

IH

Input HIGH Voltage

[12]

V

REF

+ 0.1

V

DDQ

+0.3

V

V

IL

Input LOW Voltage

[12, 13]

–0.3

V

REF

– 0.1

V

V

IN

Clock Input Voltage

–0.3

V

DDQ

+ 0.3

V

I

X

Input Load Current

GND

≤ V

I

≤ V

DDQ

−5

5

µA

I

OZ

Output Leakage Current GND

≤ V

I

≤ V

DDQ,

Output Disabled

−5

5

µA

V

REF

Input Reference Voltage

[15]

Typical Value = 0.75V

0.68

0.75

0.95

V

I

DD

V

DD

Operating Supply

V

DD

= Max., I

OUT

= 0 mA,

f = f

MAX

= 1/t

CYC

133 MHz

700

mA

167 MHz

800

mA

I

SB1

Automatic

Power-down Current

Max. V

DD

, Both Ports

Deselected, V

IN

≥ V

IH

or

V

IN

≤ V

IL

f = f

MAX

= 1/t

CYC,

Inputs Static

133 MHz

450

mA

167 MHz

470

mA

AC Electrical Characteristics

Over the Operating Range

Parameter

Description

Test Conditions

Min.

Typ.

Max.

Unit

V

IH

Input High (Logic 1) Voltage

V

REF

+ 0.2

V

V

IL

Input Low (Logic 0) Voltage

V

REF

– 0.2

V

Notes:

9. All Voltage referenced to Ground.

10. Output are impedance controlled. Ioh=-(Vddq/2)/(RQ/5) for values of 175 ohms <= RQ <= 350 ohms.
11. Output are impedance controlled. Iol=(Vddq/2)/(RQ/5) for values of 175 ohms <= RQ <= 350 ohms.
12. Overshoot: V

IH

(AC) < V

DDQ

+0.85V (Pulse width less than t

CYC

/2), Undershoot: V

IL

(AC) > -1.5V (Pulse width less than t

CYC

/2).

13. This spec is for all inputs except C and C clocks. For C and C clocks, V

IL

(Max.) = V

REF

– 0.2V.

14. Power-up: Assumes a linear ramp from 0v to V

DD

(min.) within 200ms. During this time V

IH

< V

DD

and V

DDQ

< V

DD

15. V

REF

(Min.) = 0.68V or 0.46V

DDQ

, whichever is larger, V

REF

(Max.) = 0.95V or 0.54V

DDQ

, whichever is smaller.

[+] Feedback

This manual is related to the following products: