beautypg.com

Capacitance, Ac test loads and waveforms – Cypress CY7C1312AV18 User Manual

Page 11

background image

CY7C1310AV18

CY7C1312AV18

CY7C1314AV18

PRELIMINARY

Document #: 38-05497 Rev. *A

Page 11 of 21

Capacitance

[20]

Parameter

Description

Test Conditions

Max.

Unit

C

IN

Input

Capacitance

T

A

= 25

°C, f = 1 MHz,

V

DD

= 1.8V

V

DDQ

= 1.5V

5

pF

C

CLK

Clock Input Capacitance

6

pF

C

O

Output Capacitance

7

pF

AC Test Loads and Waveforms

Note:

20. Tested initially and after any design or process change that may affect these parameters.

1.25V

0.25V

R = 50

5 pF

INCLUDING

JIG AND

SCOPE

ALL INPUT PULSES

Device

R

L

= 50

Z

0

= 50

V

REF

= 0.75V

V

REF

= 0.75V

[12]

0.75V

Under
Test

0.75V

Device
Under
Test

OUTPUT

0.75V

V

REF

V

REF

OUTPUT

ZQ

ZQ

(a)

RQ =
250

(b)

RQ =
250

Slew Rate = 2V / ns