Capacitance, Ac test loads and waveforms – Cypress CY7C1312AV18 User Manual
Page 11
CY7C1310AV18
CY7C1312AV18
CY7C1314AV18
PRELIMINARY
Document #: 38-05497 Rev. *A
Page 11 of 21
Capacitance
[20]
Parameter
Description
Test Conditions
Max.
Unit
C
IN
Input
Capacitance
T
A
= 25
°C, f = 1 MHz,
V
DD
= 1.8V
V
DDQ
= 1.5V
5
pF
C
CLK
Clock Input Capacitance
6
pF
C
O
Output Capacitance
7
pF
AC Test Loads and Waveforms
Note:
20. Tested initially and after any design or process change that may affect these parameters.
1.25V
0.25V
R = 50
Ω
5 pF
INCLUDING
JIG AND
SCOPE
ALL INPUT PULSES
Device
R
L
= 50
Ω
Z
0
= 50
Ω
V
REF
= 0.75V
V
REF
= 0.75V
0.75V
Under
Test
0.75V
Device
Under
Test
OUTPUT
0.75V
V
REF
V
REF
OUTPUT
ZQ
ZQ
(a)
RQ =
250
Ω
(b)
RQ =
250
Ω
Slew Rate = 2V / ns
This manual is related to the following products: