IDX BMS User Manual
Page 55

User Guide for Battery Management System Ver4.2
Page 55/75
IDX Company, Ltd.
3) Battery data after the second full charge
* The screen displays charge data in the order in which it was obtained,
beginning with the most
recent data shown at the top
.
* Because the date of the first full charge is recorded in Date of First Full Charge, the charge data
shown in Charge Record applies to
the second charge and onward
.
* In relation to Number of Cycles, the BMS
counts as one cycle any charge that takes place after a
continuous discharge of 10% or more of the current capacity
.
5.
Necessary conditions for the recording of Charge and Discharge Data
1) Discharge data
The system will record data of all continuous discharges of one minute or more with a load of 3 W or
above. To enable correct recording, the load must be removed after each discharge.
2)Charge data
Data will be recorded after a full charge.
* Only the three most recent charges (or discharges) can be recorded in the battery or BMS-VR. Recording
the fourth charge (or discharge) will overwrite the data of the oldest charge (or discharge).
A record of the second charge is
shown in Charge Record.
Cycles are counted in Number of Cycles.