L-gage® lt7 long-range time-of-flight sensor – Banner L-GAGE LT7 Series User Manual
Page 10
L-GAGE® LT7 Long-Range Time-of-Flight Sensor
Banner Engineering Corp. • Minneapolis, MN U.S.A
www.bannerengineering.com • Tel: 763.544.3164
10
P/N 120244 Rev. B
Main
Menu Procedure
Example Displays
Results
OFFSET
< 0 >
NOTE: Selected Offset value applies to all outputs equally.
Press
ESC
to enter Offset menu.
OFFSET
0
-then-
OFFSET
426
-or-
OFFSET
->CLEAR?
• Used to zero sensor to predetermined setting.
• Expressed in either mm or hundredths of an inch, depending on
Unit selected (see below).
• Displayed Offset value is equal to the previously programmed
setting, followed by the current sensing distance.
• See following steps for procedure if other than Offset Value is
selected.
• If no value was previously entered, current sensing distance will
be displayed; see steps below.
• If a value is currently entered, the first option will be Offset
Clear?
To Clear Offset, press
ESC
OFFSET
CLEARED!
Sensor clears Offset Value setting and returns to Main menu.
To Adjust Offset:
If no value was previously entered,
current sensing distance will be
displayed.
Press
ESC
to save current sensing
distance.
-or-
Use
ESC
and
ESC
to activate
Offset Value adjustment.
OFFSET
0
-then-
OFFSET
426
Cursor blinks on right-hand digit.
Press
ESC
or
ESC
to
decrease or increase value of each
digit;
ESC
or
ESC
also toggles left-
hand digit between + and -.
Press
ESC
to save digit and move
blinking cursor one position to left.
OFFSET
- 428
Sensor saves each digit sequentially (including + or - sign).
When cursor is at left-hand digit
and value is correct, press
ESC
OFFSET
< -428>
Sensor saves setting and returns to Main menu.
UNIT
< MM >
Press
ESC
Press
ESC
or
ESC
to toggle
between mm and inch options.
UNIT
->MM
– or –
UNIT
->INCH
Sensor is ready to accept new unit setting.
Select measurement in millimeters or inches (actually, hundredths
of an inch. To “see” whole inches on the display, imagine a
decimal point, two spaces in from the right.)
When correct option is displayed,
press
ESC
.
DIST mm
<5392>
Sensor saves setting and returns to Main menu.