Specifications – Banner SureCross DX80 Wireless Networks User Manual
Page 8

I/O
Modbus Holding Register
I/O Type
Units
I/O Range
Holding Register Repre-
sentation
Terminal
Block La-
bels
Gate-
way
Any Node
Min.
Max.
Min. (Dec.)
Max. (Dec.)
10
10
10 + (Node# × 16)
Discrete OUT 2
-
0
1
0
1
DO2
...
15
15
15 + (Node# × 16)
Control Message
16
16
16 + (Node# × 16)
Reserved
Specifications
Radio and General
Range
900 MHz: Up to 4.8 kilometers (3 miles)
2.4 GHz: Up to 3.2 kilometers (2 miles)
Transmit Power
900 MHz: 21 dBm conducted
2.4 GHz: 18 dBm conducted, less than or equal to 20
dBm EIRP
900 MHz Compliance (150 mW Radios)
FCC ID TGUDX80 - This device complies with FCC
Part 15, Subpart C, 15.247
IC: 7044A-DX8009
2.4 GHz Compliance
FCC ID UE300DX80-2400 - This device complies with
FCC Part 15, Subpart C, 15.247
ETSI/EN: In accordance with EN 300 328: V1.7.1
(2006-05)
IC: 7044A-DX8024
Spread Spectrum Technology
FHSS (Frequency Hopping Spread Spectrum)
Link Timeout
Gateway: Configurable
Node: Defined by Gateway
Radio range is with the 2 dB antenna that ships with the product.
High-gain antennas are available, but the range depends on the
environment and line of sight. To determine the range of your wire-
less network, perform a Site Survey.
Power
Requirements: +10 to 30V dc or +3.6 to 5.5V dc low
power option (Outside the USA: +12 to 24V dc, ±10%
or +3.6 to 5.5V dc low power option)
Consumption: Less than 1.4 W (60 mA) at 24V dc
Housing
Polycarbonate housing and rotary dial cover; polyester
labels; EDPM rubber cover gasket; nitrile rubber, non-
sulphur cured button covers
Weight: 0.26 kg (0.57 lbs)
Mounting: #10 or M5 (SS M5 hardware included)
Max. Tightening Torque: 0.56 N·m (5 lbf·in)
Antenna Connection
Ext. Reverse Polarity SMA, 50 Ohms
Max Tightening Torque: 0.45 N·m (4 lbf·in)
Interface
Indicators: Two bi-color LEDs
Buttons: Two
Display: Six character LCD
Wiring Access
Four PG-7, One 1/2-inch NPT, One 5-pin Euro-style
male connector
For European applications, power the DX80 from a Limited Power
Source as defined in EN 60950-1.
Inputs and Outputs
Discrete Inputs
Rating: 3 mA max current at 30V dc
Sample/Report Rates: DIP switch configurable (see ta-
bles)
Discrete Input ON Condition
PNP: Greater than 8V
NPN: Less than 0.7V
Discrete Input OFF Condition
PNP: Less than 5V
NPN: Greater than 2V or open
Discrete Output Rating (NMOS)
Less than 10 mA max current at 30V dc
ON-State Saturation: Less than 0.7V at 20 mA
Discrete Output
Update Rate: 1 second
ON Condition: Less than 0.7V
OFF Condition: Open
Output State Following Timeout
De-energized (OFF)
SureCross DX80 FlexPower Node
8
www.bannerengineering.com - tel: 763-544-3164
P/N 131296 Rev. L