Boss Audio Systems SP-505 User Manual
Page 79
79
Chapter 15. Appendices
6
Appendices
Song REC Full!
❍
No more can be recorded in this song, since the
maximum number of patterns in one song has been
exceeded.
→
A maximum of 999 patterns can be registered as part of
one song. No further patterns can be registered.
■
Card related
WARNING! Turn OFF Power Data
Maybe Damaged!
❍
A card was inserted or removed while the power was
on, or the power was turned on when a card was
inserted halfway.
→
Turn off the power, remove the card or insert it correctly,
and then turn the power on once again.
Memory Full!
❍
Data cannot be saved, since there is insufficient space
remaining on the memory card.
→
❍
There is not enough memory to load the WAV/AIFF
file.
→
Delete unneeded samples. (p. 49)
→
Reduce the size of the WAV/AIFF file.
Protected!
❍
Sampling to a memory card bank is not possible
because a write-protect sticker is affixed to the memory
card.
→
Remove the write-protect sticker from the memory card.
❍
Data cannot be saved because a write-protect sticker is
affixed to the memory card.
→
Remove the write-protect sticker from the memory card.
Unsupported Format!
❍
The format of the inserted memory card is a format that
the SP-505 cannot use.
→
The SP-505 is able to use only 8–128 MB Smart Media
memory cards with a 3.3 V power supply. Please check
the type of card you are using.
❍
Loading/saving is not possible because the sample or
sequencer data is corrupted.
→
Either erase (p. 69) the offending data, or format the
memory card (p. 66).
❍
You are attempting to load a WAV/AIFF file that
cannot be loaded into the SP-505.
→
Read the cautionary notes regarding the loading of
WAV/AIFF files. (p. 70)
■
System related
Too Busy
❍
The data could not be processed fast enough.
→
Operate the buttons or VALUE dial more slowly.
Memory Damaged
❍
The contents of internal memory have been destroyed.
→
Perform the Initialize operation as directed by the
display.
If this does not resolve the problem, contact a nearby