4. Find irregular Jack lengths:
[Conv] [Jack]
IJOC 16 INCH
[Jack]*
IJ1 2 FEET 9-5/8 INCH
[Jack]
IJ2 1 FEET 4-13/16 INCH
[Jack]
IJ3 0 FEET 0 INCH
ю
ю
*
Note: It is not necessary to continue pressing [Conv] when display-
ing each Jack rafter size.
5. Find irregular Jack Plumb, Level and Cheek cut angles:
[Jack]
PLMB 33.69
°°
[Jack]
LEVL 56.31
°°
[Jack]
CHK1 41.19
°°
6. Find regular Jack lengths:
[Jack]
JKOC 16 INCH
[Jack]
JK1 2 FEET 10-3/8 INCH
[Jack]
JK2 1 FEET 1-1/4 INCH
[Jack]
JK3 0 FEET 0 INCH
7. Find regular Jack Plumb, Level and Cheek cut angles:
[Jack]
PLMB 30.26
°°
[Jack]
LEVL 59.74
°°
[Jack]
CHK1 48.81
°°