beautypg.com

Cables exit in the center – Rockwell Automation LDL Ironless Linear Servo Motors User Manual

Page 36

background image

36

Publication LDL-UM001A-EN-P - March 2009

Chapter 5 Wiring the LDL-Series Linear Motor

Cables Exit in the Center

If mounting coils in tandem, such that the power cables exit in the
center, as shown, use the following table to find mounting distance
and phase wiring.

160 (6.30)

Red

Red

U

White

White

V

Black

Black

W

(1) Master has Hall effect module.
(2) Slave has no Hall effect module.

Phase Wiring for Right Exit Power Cables

L1
mm (in.)

Coil # 1
Master

(1)

Coil # 2
Slave

(2)

Amplifier
Phase

L1

Coil #1 is the master

Coil #1

Coil #2

Hall Effect

Phase Wiring for Center Exit Power Cables

L1
mm (in.)

Coil # 1
Master

(1)

Coil # 2
Slave

(2)

Amplifier
Phase

90 (3.54)
or
150 (5.91)

Red

White

U

White

Red

V

Black

Black

W

(1) Master has Hall effect module.