beautypg.com

Rockwell Automation 9000 Series Sensor User Manual

Page 12

background image

4

Entek 9000 Series Sensor Installation Guide

9000 Series Sensors

High Temperature

9100T 43805I 8–14 VDC

100 mV/g High temperature

accelerometer

Top exit, Mil Spec connector,
-54 to 163 deg C operating
range.

9150HT 43807I 12–15 VDC

100 mV/g High temperature charge

mode accelerometer
system

Top exit, 2-Pin Mil Spec
connector, -54 to 260 deg C
operating range.

9150HTA 46496 12–15 VDC

100 mV/g High temperature charge

mode accelerometer
system

Top exit, 2-Pin Mil Spec
connector, -54 to 260 deg C
operating range. Armored
cable.

9200T 43806I 11–14 VDC

100 mV/g High temperature, low

profile ring style
accelerometer

Side exit, Mil Spec connector,
-54 to 163 deg C operating
range.

Velocity Output

9100VO 43808I 8–12 VDC 100 mV/in/sec Velocity output

accelerometer

Top exit, Mil Spec connector.

9200VO 43809I 8–12 VDC 100 mV/in/sec Velocity output, low

profile ring style
accelerometer

Side exit, Mil Spec connector.

Model

Number

Part

No

Bias

Output

Sensitivity

Description Notes