Connector data – Rockwell Automation TL-Series Servo Motor User Manual
Page 13

TL-Series Servo Motor Installation Instructions 13
Publication TL-IN001C-EN-P — March 2005
Connector Data
This table provides signal descriptions for the flying leads on all TL-Series motors.
Absolute Encoder
Incremental Encoder
Feedback Connector
Feedback Connector
Connector Housings
Pin
Signal
Pin
Signal
1-6
Reserved
—
1
A+
green
7
EPWR red
2
A-
green/blk
8
ECOM and brown/blk
3
B+
blue
BAT- blk
4
B-
blue/blk
9
SHIELD blk
shrink 5
I+
yellow
10-11 Reserved
—
6
S1
gray/blk
12
SD+ blue 7
+5V
DC
red
13
SD- blue/blk
8
ECOM
black
14
BAT+
brown 9
SHIELD
blk
shrink
15
Reserved
—
10
I-
yellow/blk
Power Connector
11
S2
brown/blk
Pin
Signal
12-14 Reserved
—
1
U phase
red
15
S3
white/blk
2
V phase
white
Power Connector
3
W phase
black
Pin
Signal
4
Ground yellow/grn
1
U
phase red
Brake Connector
2
V phase
black
Pin
Signal
3
W phase
white
1
BR+ yellow
4
Ground
yellow/grn
2
BR-
-A410 only
blue
yellow
Brake Connector
Pin
Signal
See page 14 for additional
information about these
AMP™ connectors.
1
BR+
yellow
2
BR-
-A410 only
blue
yellow
!
ATTENTION
Ensure that cables are installed and restrained to prevent
uneven tension or flexing at the cable connectors.
Excessive and uneven force at the cable connector may result in
damage to the housing and contacts as the cable flexes.
Failure to observe these safety procedures could result in
damage to the motor and its components.