Environmental (specifications assume standard configuration,
excluding diskette drive)
Temperature

Operating

+5 °C to +45°C

Storage

-30°C to +60°C

Relative Humidity

8% to 80% non-condensing

Altitude

Operating

To 10,000 ft. (3,000m)

Non-Operating

To 40,000 ft. (12,000m)

Vibration

Operating

0.1in. p-p, 5-14 Hz sine;
1.0g peak, 14-500 Hz sine

Non-Operating

0.1 in. p-p, 5-14 Hz sine;
2.0g peak, 14-500 Hz sine

Shock

Operating

10g (1/2 sine, 11 msec)

Non-operating

30g (1/2 sine, 11 msec)

Electrical
Line voltage

90-132V AC,
180-264V AC auto-switching

Line Frequency

47-63 Hz

Power Consumption

150W typical, 300W max.

Safety
Electric Shock, Fire

UL / C-UL 1950 listed
EN60950

X-Ray Emissions

N/A

Physical
Bulletin 6155 Dimensions

Refer to Figure 1 (page 1-2)

Net Weight

35 lb. (16 kg)

Agency Approval

CE

A-2

Bulletin 6155 Industrial Computer

Publication 6155-IN001C-EN-P