European union directive compliance, Hazardous locations – Rockwell Automation VersaView 1200P Integrated Display Computers for Hazardous Locations User Manual
Page 3

VersaView 1200P Integrated Display Computers for Hazardous Locations 3
Publication 6183H-IN001E-EN-P - July 2007
European Union Directive Compliance
within the European Union or EEA regions and has the CE mark. See http
for declarations of conformity, certificates, and other certification details.
Hazardous Locations
This equipment is suitable for:
• Class I, Zone 2, Group IIC.
• Class I, Division 2, Groups A, B, C, D.
• nonhazardous locations.
The dc powered touch-screen and non-display units are additionally suitable for
European Zone 2 applications as defined by EU Directive 94/9/CE (ATEX) as it
relates to Category 3 equipment intended for use in potentially explosive
atmospheres given in Annex II of this directive per EN60079-15:2003.
The units are rated:
• II 3G EEx nL IIC T4.
• 0 °C ≤ T
amb
≤ 50 °C.
• Certificate: DEMKO 06 ATEX 0627219 X.
ATTENTION
This product is intended to operate in an industrial or control room
environment, which utilizes some form of power isolation from the public
low-voltage mains. Some computer configurations may not comply with the EN
61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of
the European Union. Obtain permission from the local power authority before
connecting any computer configuration that draws more than 75 W of ac power
directly from the public mains.
ATTENTION
To comply with EN 55024, the Ethernet port LAN cable must be less than 30 m
(98.42 ft), and it must only be used indoors (not exit the building at any point).
All other I/O cables must be less than 3 m (9842 ft), and must only be used
indoors.