Rockwell Automation 8520-OM Offline Development System User Manual User Manual
Page 78
7--4
Using ODS Communication Configuration
Publication 8520--UM051A--EN--P -- October 2000
Offline Development Manual (ODS) Software User Manual
Figure 7.3
Configuration Flow for the 1784-KL or 1784-KT
Select the communications port that will be used for Data Highway Plus
communications.
Select the address of the driver card that will communicate over the
Data Highway Plus (PLC). This address must match the address selected
on the switch setting on the 1784-KT module. Address range is 10 binary
digits for the 1784-KL driver and six digits for the 1784-KT driver. The
Select the station address of the ODS terminal on the Data Highway Plus.
Address range is from 0 to 77 (octal). The default value is 77.
default value is 2400 baud.
Select the baud rate using the Data Highway Plus communications. The
Select the station address of the logic controller on the Data Highway Plus.
Address range is from 0 to 77 (octal). The default is 02.
Select the type of connection used on the Data Highway Plus. Direct
indicates only a logic controller and the ODS terminal are connected.
Multidrop indicates more than one logic controller and ODS terminal are
connected. The default selection is Direct.
Select the network access, Local or Remote, when using the 1784-KT
module. The default selection is Local.
Select the local or remote bridge address. The address range is
0 through 376 (octal). The default value is 110.
Select the IMC rack address. The address range is 0 through 7.
Select the IMC group address. The address range is 0 through 7.
Select the delay time between Block Transfer read/write requests and Block
Transfer read requests to get the status from the last BLT. The delay time
range is 0 to 9999 milliseconds. The default value is 2500.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
1784-KT Driver Type
1784-KL Driver Type
Port Type Desired
Address of Driver Card
DH+ Station Address of Terminal
Baud Rate of Driver
Connection Type Desired
Network Access
Bridge Address
DH+ Station Address
of Logic Controller
Handshake Delay
IMC-12x Rack Address
IMC-12x Group Address
The default value is 0. IMC 12x includes IMC--120, IMC--121,
IMC--123, and IMC--123CR.
The default value is 0. IMC 12x includes IMC--120, IMC--121,
IMC--123, and IMC--123CR.
default value is 00001, 10000 for the 1784--KL, and 000011 for the 1784--KT.