Figure 6 - typical wiring a – Rockwell Automation 1902 Syncpro II User Manual
Page 26
28
Rockwell Automation Publication 1902-IN001B-EN-E - April 2013
Chapter 3
Installation
Figure 6 - Typical Wiring A
L1
____V AC, 3Ø
, _
_H
z
IS
O
LA
T
IN
G
SWIT
CH
DOOR INT
E
R
LOC
K
CURRENT
LIMI
TI
N
G
GR
D
L2
L3
POWE
R FU
SE
S
R1
R2
(-)
(+)
F1
F2
G
N
P
C
V
(+)
PULSE CONVER
TER
ANALOG/DI
GI
TAL
R
W
BL
K
(-)
DANGER
AUTOMATIC
A
LL
Y
.
SEVERE INJURY OR
D
E
A
T
H
.
O
F
LO
AD CAN RESU
LT
IN
UNEXPECTED ENER
GI
ZATI
ON
RESET
T
ING ANY
D
E
VI
C
E
.
CONT
RO
L S
IG
N
AL
BEFORE
REMOVE MAIN C
O
N
T
A
C
TOR
CONT
RO
LLER
MAY AUTOMATI
C
A
LL
Y
RESET OR
R
E
S
E
T
S
STAR
T/
RE
-S
TA
RT AF
TE
R
A
P
R
O
T
E
C
T
IV
E
D
EVICE IS
!
REFER TO DIMENSION DRAWING F
O
R CO
MPO
N
EN
T
SIZ
ING NOT SH
OWN ON TH
IS
DRAWI
N
G
.
REMOTE EQU
IP
M
E
N
T
LO
W
V
O
LT
A
G
E
D
O
O
R
M
O
UNT
ED
DEVICE
"IEEE" NUMBER FOR PROTEC
TI
VE D
E
VI
C
E
CUSTOMER
W
IRING
NOT
E
S
NOT
E
S
NOT
E
S
D
LEGEN
D
LEGEN
D
LEGEN
D
SYNCHRON
OU
S
MOTOR
MP
S
COM
INPUT 1
INPUT 2
Y1-
Y12
Y14
RX
BUL. 825P MO
DULA
R P
R
O
T
ECTIVE SYSTEM
AUX 2
CBCT
PTC
(THERMI
ST
OR
)
INPUT
ALARM
AUX 1
TO MC
M
COM
COM
INPUT 3
INPUT 3
INPUT 5
INPUT 5
INPUT 4
INPUT 4
OUTP
UT
OUTP
UT
ANALOG
ANALOG
54 54
43 43
44 44
53 53
33 33
34 34
I- I-
I+ I+
63 63
64 64
Y26
Y26
Y22
Y22
Y24
Y24
Y2-
Y2-
12
0 V
P
IO
O
P
T
ION
CARD
AUX
AUX
AUX
AUX
TR
IP
24
S1
S2
13
23
14
A2-
98
95
96
A1+
T1
T2
3
4
5
6
F
R
O
N
T
PANEL
LO
CA
L P
R
O
G
RAMMING
POR
T
POWER
FAI
LS
A
F
E
FAI
LS
A
F
E
NON
RS232
POWER APPLIED. T
H
E F
O
LLO
W
ING FAC
T
ORY IN
STALLED
OUT
PUT
RELAY CO
NT
ACT
S
SHOWN WI
THOUT CONTROL
BUL
.82
5P TO BE PROGRAMMED B
Y
TH
E
C
U
S
TOM
E
R
AUX.1/ALARM - NON
FAI
L
SAFE
CONT
ACT
PO
W
E
R-
UP
S
T
A
T
ES ARE IN EFFECT:
BEFORE STA
R
T-U
P
.
AUX.2 -
NON F
A
IL
SAFE
TR
IP
- FAI
L
S
A
F
E
BUL.825P NOTES:
D
2
1
46
35
CO
NV
E
R
T
E
R
MODULE
BLK
W
PRIM
A
R
Y
FUSES
CURRENT
LIMI
TI
N
G
F
R
O
M
RE
CT
IF
IE
R
ASSEMBLY
SHT
.2, LINE K-2
38
F
ROM SH
T.
4
LINE H-
41
5
F
R
O
M
RE
CT
IF
IE
R
ASSEMBLY
SHT
.2, H-2
38
LINE C-
30
1
BLK
B
R
W
DEVICE
N
E
T
OPTION C
A
R
D
T
O
DEVICENET
N
E
TWOR
K
RT
D 1 -
RTD
1
2
BUL.825P RT
D MOD
U
LE
MPSR
TD
+
23
+
24
N
240VAC
120VAC
N
25
26
NO
T
USED
19
20
21
22
FI
BR
E O
P
T
IC
CONNEC
TOR
SHOWN ON
SH
T.
3
500M MAX.
L3
L2
L1
N
PH
AS
E
VOLTAGE
INPU
T
M
IO
O
P
T
IO
N
CARD
(O
PT
IO
NA
L)
AND/O
R
P
R
O
T
E
C
T
IO
N
RELAYS.
W
IL
L O
V
E
R
R
ID
E
M
E
T
E
R
ING DEVICES
USE OF SHORT
ING T
E
R
M
IN
A
L B
LOC
K
CAUT
ION
:
SHORTI
N
G
TER
M
IN
A
L
BLOC
K
BLK
W
PH
AS
E A
NG
LE
TR
ANSDUCER
BLK
W
V
VA
V
DANGER
INDUCED F
IE
LD VOLTAGES
HIG
H
VOL
T
AGE
CONT
ACT WI
TH
SYNCHRONOUS MOTOR
EXCEED 1000 VOL
TS.
STARTING A
N
D
M
A
Y
IN SEVERE INJU
R
Y
.
F
IELD CO
NN
EC
TED
CO
M
P
O
N
E
N
T
S
C
A
N
RESULT
O
R
DEATH
A
R
E
P
R
E
S
E
N
T
DURING
!
LIVE CIRC
U
IT
MORE THAN
ON
E
DANGER
!
LINE B-
20
2
3 PHASE
H3
X3
H1
H2
X1
X2
VV
VV
TO SH
T
.3
TO SH
T
.2
TO SH
T
.3
LINE D-
33
1
F
ROM SH
T.
3
LINE E-3
37
LINE N-
30
2
TO SH
T
.3
LINE C-
31
8
TO SH
T
.3
LINE D-
33
0
90
91
VB
PT
____
____
120
120
FFF
__E
__E
__E
VC
VB
VA
____
120
500
CPT
VA
A
VC
A
F5
1.0A
F5
1.0A
47A
46B
44A
42A
STB
PAT
1
12
52
1
12
51
__E
F2
6
__E
F2
5
ISa
7
46A
47
46
44
42
CM
GFC
T
100:1
113
1L2A
1L1A
104
103
M
101
RF
102
RF
105
A/DPC
F1
F2
CT1
CT3
CT2
T3
T2
T1
RD
304
F1
F1
F1
IS