Rockwell Automation 1799-D10U10VZC Zone Control I/O Cards User Manual
Page 12

12 Zone Control I/O Cards
Publication 1799-IN007D-EN-P - October 2005
The 1799-ZCIOV and 1799-D10U10VZC cards have outputs that receive current from your
field output device (sinking outputs). Use the following wiring diagram to configure the
outputs on this card.
1799-ZCIOV and -D10U10VZC Outputs (Sinking)
Connect the Field Input Device to the Input Connector (P4)
The 1799-ZCIOB, 1799-D10U10BZC, 1799-ZCIOV, and 1799-D10U10VZC cards have
universal inputs that provide operation with either sourcing or sinking input devices. The
universal feature lets you configure the inputs as either all sinking or all sourcing. Use the
following wiring diagrams to connect the inputs on the cards.
IMPORTANT
All field input devices in each group of eight must be of the same type,
either sinking or sourcing. The card will not operate if the types are mixed.
Load
0
2 24V dc
Return
3
4
5
6 24V dc 7
8
9
1
43091