Hazardous location approval, Back cover – Rockwell Automation 1792D-16BVT0CD ArmorBlock MaXum 16 Input Module with Complete Diagnostics User Manual
Page 16
Publication 1792D-IN053A-EN-P - August 2002
PN 957689-17
Copyright © 2002 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Hazardous Location Approval
ArmorBlock, ArmorBlock MaXum, and KwikLink are trademarks of Rockwell Automation. RSNetWorx
for DeviceNet is a trademark of Rockwell Software Inc. DeviceNetManager is a trademark of Rockwell
Automation Allen-Bradley, Inc. DeviceNet is a trademark of Open DeviceNet Vendor Association.
The following information applies when operating
this equipment in hazardous locations:
Informations sur l’utilisation de cet équipement en
environnements dangereux :
Products marked “CL I, DIV 2, GP A, B, C, D” are suitable
for use in Class I Division 2 Groups A, B, C, D, Hazardous
Locations and nonhazardous locations only. Each product
is supplied with markings on the rating nameplate
indicating the hazardous location temperature code.
When combining products within a system, the most
adverse temperature code (lowest “T” number) may be
used to help determine the overall temperature code of
the system. Combinations of equipment in your system
are subject to investigation by the local Authority Having
Jurisdiction at the time of installation.
Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne
conviennent qu’à une utilisation en environnements de
Classe I Division 2 Groupes A, B, C, D dangereux et non
dangereux. Chaque produit est livré avec des marquages sur
sa plaque d’identification qui indiquent le code de
température pour les environnements dangereux. Lorsque
plusieurs produits sont combinés dans un système, le code
de température le plus défavorable (code de température le
plus faible) peut être utilisé pour déterminer le code de
température global du système. Les combinaisons
d’équipements dans le système sont sujettes à inspection
par les autorités locales qualifiées au moment de
l’installation.
WARNING
!
EXPLOSION HAZARD
•
Do not disconnect
equipment unless
power has been
removed or the area is
known to be
nonhazardous.
•
Do not disconnect
connections to this
equipment unless
power has been
removed or the area is
known to be
nonhazardous. Secure
any external
connections that mate
to this equipment by
using screws, sliding
latches, threaded
connectors, or other
means provided with
this product.
•
Substitution of
components may impair
suitability for Class I,
Division 2.
•
If this product contains
batteries, they must
only be changed in an
area known to be
nonhazardous.
AVERTISSEMENT
!
RISQUE D’EXPLOSION
•
Couper le courant ou
s’assurer que
l’environnement est
classé non dangereux
avant de débrancher
l'équipement.
•
Couper le courant ou
s'assurer que
l’environnement est
classé non dangereux
avant de débrancher les
connecteurs. Fixer tous
les connecteurs
externes reliés à cet
équipement à l'aide de
vis, loquets coulissants,
connecteurs filetés ou
autres moyens fournis
avec ce produit.
•
La substitution de
composants peut rendre
cet équipement
inadapté à une
utilisation en
environnement de
Classe I, Division 2.
•
S’assurer que
l’environnement est
classé non dangereux
avant de changer les
piles.