Din rail mounting, Install the switch – Rockwell Automation 1783-EMS08T Stratix 6000 Ethernet Managed Switches Installation Instructions User Manual
Page 8
8 Stratix 6000 Ethernet Managed Switches
Rockwell Automation Publication 1783-IN004B-EN-P - June 2014
DIN Rail Mounting
Read this section for information on how to install and remove a switch using
DIN rail mounting.
Install the Switch
To install the switch on DIN rail, proceed as follows.
1. Mount your DIN rail.
2. Snap the DIN-rail latch into the closed position.
3. Hook the top slot over the DIN rail and push the switch into position
on the DIN rail.
WARNING: If you connect or disconnect the communication cable with power
applied to this module or any device on the network, an electrical arc can occur. This
could cause an explosion in hazardous location installations.
Be sure that power is removed or the area is nonhazardous before proceeding.
WARNING: If you connect or disconnect wiring while the field-side power is on, an
electrical arc can occur. This could cause an explosion in hazardous location
installations. Be sure that power is removed or the area is nonhazardous before
proceeding.