Rockwell Automation 1734-IK/C POINT I/O 5V and 24V Encoder/Counter Module Installation Instructions User Manual
Page 20
20 POINT I/O™ 5V and 24V Encoder/Counter Modules
Publication 1734-IN005G-EN-E - September 2012
Environmental Specifications
Attribute
Value
Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-20…55 °C (-4…131 °F)
Temperature, storage
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock):
-40…85 °C (-40…185 °F)
Relative humidity
IEC 60068-2-30 (Test Db, Unpackaged Nonoperating Damp Heat):
5…95% noncondensing
Vibration
IEC60068-2-6 (Test Fc, Operating):
5 g @ 10…500 Hz
Shock, operating
EC 60068-2-27 (Test Ea, Unpackaged Shock):
30 g
Shock, nonoperating
EC 60068-2-27 (Test Ea, Unpackaged Shock):
50 g
Emissions
CISPR11
Group 1, Class A
ESD immunity
IEC6100-4-2:
6 kV contact discharges
8 kV air discharges
Radiated RF immunity
IEC 61000-4-3:
10V/m with 1 kHz sine-wave 80% AM @ 30…2000 MHz
10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz
EFT/B immunity
IEC 61000-4-4:
±4 kV at 2.5 kHz on signal ports
Surge transient immunity
IEC 61000-4-5:
±1 kV line-line (DM) and
±2 kV line-earth (CM) on signal ports
Conducted RF immunity
IEC61000-4-6:
10 V rms with 1 kHz sine-wave 80%AM @ 150 kHz…80 MHz