Wiring the Home Limit Switch Input

The home limit switch inputs to the servo module are designed for 24V
nominal operation. These inputs should be wired for current sourcing
operation.

Figure 18 Home Limit Switch

Wiring the OK Contacts

A set of isolated solid-state OK relay contacts is provided for optional
interface to an E-stop string, which controls power to the associated drives.
The OK contacts are rated for pilot duty and can drive an external 24V relay
(for example, Allen-Bradley 700-HA32Z24) whose contacts can be
incorporated into the E-Stop string as shown below.

24 VDC

Field Power

Supply

HOME

IN_COM

General Cable

C0720

From 1756-M02AE

+

-