Specifications, Machinery directive – Rockwell Automation 1756-L72EROMS Armor GuardLogix Controller User Manual
Page 22

22 Armor GuardLogix Controller
Rockwell Automation Publication 1756-IN060B-EN-P - November 2013
Specifications
This section lists general specifications specific to the enclosure. Specifications for the
components in the Armor GuardLogix controller enclosure are in their respective Technical
Data publications, listed in the
Additional Resources on page 23
Machinery Directive
The controllers are in conformity with the essential requirements of the Machinery Directive
(2006/42/EC) when installed in accordance with the instructions contained in the product
documentation. The standards, and technical specifications referred to below have been applied
as indicated.
Attribute
1756-L72EROMS
Input System Power - Unswitched (Pins 2 and 3)
18 …32V DC @ 8 A
Input Pass Through Power - Switched (Pins 1 and 4)
18…32V DC @ 8 A
Output External Power - Unswitched (Pins 2 and 3)
18…32V DC @ 6 A
Output Pass Through Power - Switched (Pins 1 and 4)
18…32V DC @ 8 A
Enclosure type rating
Meets IP65/67 (when marked) with receptacle dust caps or cable
termination
Temperature, operating
0…60 °C (32…140 °F)
Weight, approx
6.5 kg (14.3 lb)
Dimensions (HxWxD), approx
240 x 292 x 164.52 mm (9.4 x 11.5 x 6.5 in.)
Standard/Technical Specification
EN 60204-1
Electrical equipment of machines
EN ISO 13849-1
Safety-related parts of control systems
EN 62061
Functional Safety of safety-related control systems