ControlNet Communication Interface Card
Publication 1784-5.33 – September 1997
Worksheet B
KTCX15 switch settings
Base Memory Addr
(hex)
Switch Settings
Base Memory Addr
(hex)
Switch Settings
C000:0000
up (1)
down (0)
1 2
1 2 3 4
D000:0000
factory set default
address &
recommended setting
up (1)
down (0)
1 2
1 2 3 4
C400:0000
up (1)
down (0)
1 2
1 2 3 4
D400:0000
up (1)
down (0)
1 2
1 2 3 4
C800:0000
up (1)
down (0)
1 2
1 2 3 4
D800:0000
up (1)
down (0)
1 2
1 2 3 4
CC00:0000
up (1)
down (0)
1 2
1 2 3 4
DC00:0000
up (1)
down (0)
1 2
1 2 3 4
Worksheet C
Your base memory address
Record the base memory address for the KTCX15 card:
Card:
Slot number:
Using default address:
If no, new memory address:
yes
no
up (1)
down (0)
1 2
1 2 3 4
S2
S1
ControlNet Communication Interface Card
29
Publication 1784-5.33 – September 1997
CSA Hazardous Location Approval
CSA certifies products for general use as well as for use in hazardous locations. Actual CSA
certification is indicated by the product label as shown below, and not by statements in any
user documentation.
Example of the CSA certification product label
I
To comply with CSA certification for use in hazardous locations, the following information
becomes a part of the product literature for this CSA-certified industrial control product.
•
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D, or non-hazardous
locations only.
•
The products having the appropriate CSA markings (that is, Class I Division 2, Groups A, B,
C, D), are certified for use in other equipment where the suitability of combination (that is,
application or use) is determined by the CSA or the local inspection office having jurisdiction.
Important: Due to the modular nature of a programmable control system, the product with the
highest temperature rating determines the overall temperature code rating of a programmable
control system in a Class I, Division 2 location. The temperature code rating is marked on the
product label as shown.
Temperature code rating
Look for temperature code
rating here
I
WARNING: Explosion hazard —
•
Substitution of components may impair suitability for Class I, Division 2.
•
Do not replace components unless power has been switched off or the area
is known to be non-hazardous.
•
Do not disconnect equipment unless power has been switched off or the
area is known to be non-hazardous.
The following warnings apply to products having CSA certification for use in hazardous locations.
area is known to be non-hazardous.
•
Do not disconnect connectors unless power has been switched off or the
area is known to be non-hazardous. Secure any user-supplied connectors
that mate to external circuits on this equipment by using screws, sliding
latches, threaded connectors, or other means such that any connection
can withstand a 15 Newton (3.4 lb.) separating force applied for a minimum
of one minute.
•
Batteries must be changed only in an area known to be non-hazardous.
!
CSA logo is a registered trademark of the Canadian Standards Association.