Files that correspond to this example look like – Rockwell Automation 1747-L55x,D174710.4 SLC 500 Ethernet User Manual
Page 43
![background image](/manuals/579089/43/background.png)
4–13
Communicating on the Ethernet Network
Publication 1747-10.4
The
BOOTPTAB
files that correspond to this example look like:
#
Legend:
gw
––
gateways
#
ha
––
hardware
address
#
ht
––
hardware
type
#
ip
––
host
IP
address
#
sm
––
subnet
mask
#
vm
––
BOOTP vendor extensions format
#
tc
––
template host
#Default string for each type of Ethernet client
defaults5E: ht=1:vm=rfc1048:sm=255.255.255.0
#Entries for SLC 5/05 processors:
iota1:\
tc=defaults5E:\
gw=130.151.194.1:\
ha=0000BC1D1234:/
ip=130.151.194.19
#
Legend:
gw
––
gateways
#
ha
––
hardware
address
#
ht
––
hardware
type
#
ip
––
host
IP
address
#
sm
––
subnet
mask
#
vm
––
BOOTP vendor extensions format
#
tc
––
template host
#Default string for each type of Ethernet client
defaults5E: ht=1:vm=rfc1048:sm=255.255.255.0
#Entries for SLC 5/05 processors:
iota2:\
tc=defaults5E:\
gw=130.151.132.1:\
ha=0000BC1D5678:/
ip=130.151.132.110
#
Legend:
gw
––
gateways
#
ha
––
hardware
address
#
ht
––
hardware
type
#
ip
––
host
IP
address
#
sm
––
subnet
mask
#
vm
––
BOOTP vendor extensions format
#
tc
––
template host
#Default string for each type of Ethernet client
defaults5E: ht=1:vm=rfc1048:sm=255.255.255.0
#Entries for SLC 5/05 processors:
iota3:\
tc=defaults5E:\
gw=130.151.138.1:\
ha=0000BC1D9012:/
ip=130.151.138.123