Rockwell Automation 1336F Plus II Parameters User Manual
Page 7

1336 PLUSII Parameter Record
Machine #
Date programmed
Drive Serial #
Par #
Parameter Name
Minimum Value
Maximum Value
Factory Default
Programmed Value
38 Overload Amps
20% of Drive Rated Amps
115% of Drive Rated Amps
115% of Drive Rating
39 Flt Clear Mode
Disabled
Enabled
Enabled
40 Line Loss Fault
Disabled
Disabled
Enabled
41 Motor Type
Induction
Induction
Sync Reluc
Sync PM
42 Slip @ F.L.A.
0.0 Hz
10.0 Hz
1.0 Hz
43 Dwell Frequency
0.0 Hz
7.0 Hz
0.0 Hz
44 Dwell Time
0 Sec
10 Sec
0 Sec
45 PWM Frequency
1 KHz
A & B Frame Drives = 8 kHz
2 KHz
C Frame Drives & Up = 6 kHz
46 Encoder PPR
1
4096
1024 PPR
47 Language
English
English
FRANCAIS
ESPANOL
Italiano
Deutsch
Japanese
Portuguese
Nederlands
48 Start Boost
0 Volts
9.5% of Drive Rated Voltage
0 Volts
49 Break Frequency
0 Hz
120 Hz
25% of [Maximum Freq]
50 Break Voltage
0 Volts
50% of Drive Rated Voltage
25% of Drive Rated Voltage
51 Clear Fault
Ready
Ready
Clear Fault
52 Stop Select 2
Coast
Coast
DC Brake
Ramp
S Curve
Ramp to Hold
53 DC Bus Voltage
0
200% DC Bus Voltage Max
Read Only
54 Output Current
0
200% Rated Drive Output Current
Read Only
55 Input Status
Input 1 - TB3-19
Input 2 - TB3-20
Input 4 - TB3-23
Input 3 - TB3-22
Input 5 - TB3-24
Input 6 - TB3-26
Input 8 - TB3-28
Input 7 - TB3-27
56 S Curve Time
0.0 Sec.
1800.0 Sec
0.0 Sec
57 S Curve Enable
Disabled
Disabled
Enabled
58 Common Bus
Disabled
Disabled
Enabled
59 Drive Status 1
Enabled
Running
Command Direction
Actual Direction
Accelerating
Decelerating
Alarm
Faulted
At Speed
Local Adapter ID
Local Adapter ID
Local Adapter ID
Reference ID
Reference ID
Reference ID
Reference ID
60 Drive Alarm 1
Bus Charging
Hardware Current Limit
Motoring Current Limit
Regenerating Current Limit
Regenerating Voltage Limit
Line Loss In Progress
Mtr Overload
Motor Stalled
Ground Warning
Auxilliary Input
Heatsink Temp
Sync Loss
Phase Loss
4-20 mA Loss
Motor OL Trip
Auto Reset
61 Drive Type
Read Only
62 Freq Source
Use Last
Use Last
Analog In 0
Analog In 1
Analog In 2
Pulse Ref
MOP
Adapter 1
Adapter 2
Adapter 3
Adapter 4
Adapter 5
Adapter 6
Preset 1
Preset 2
Preset 3
Preset 4
Preset 5
Preset 6
Preset 7
Encoder
Jog Sel
Page 2 of 13