Rockwell Automation 1336F Plus II Parameters User Manual
Page 4
Par #
Parameter Name
Factory Default
Programmed Value
Par #
Parameter Name
Factory Default
Programmed Value
117
Data In D1
Read and Write
175
CR3 Out Select
Fault
118
Data In D2
Read and Write
176
CR4 Out Select
Alarm
119
Data Out A1
Read and Write
177
Motor NP RPM
1750 RPM
120
Data Out A2
Read and Write
178
Motor NP Hertz
60 Hz
121
Data Out B1
Read and Write
179
Local Owner
Read Only
122
Data Out B2
Read and Write
180
Process 2 Par
54
123
Data Out C1
Read and Write
181
Process 2 Scale
+1.00
124
Data Out C2
Read and Write
182
Process 2 Txt 1
Amps
125
Data Out D1
Read and Write
183
Process 2 Txt 2
Amps
126
Data Out D2
Read and Write
184
Process 2 Txt 3
Amps
127
Process 1 Par
1
185
Process 2 Txt 4
Amps
128
Process 1 Scale
+1.00
186
Process 2 Txt 5
Amps
129
Process 1 Txt 1
Volts
187
Process 2 Txt 6
Amps
130
Process 1 Txt 2
Volts
188
Process 2 Txt 7
Amps
131
Process 1 Txt 3
Volts
189
Process 2 Txt 8
Amps
132
Process 1 Txt 4
Volts
190
Motor NP Volts
Drive Rated Volts
133
Process 1 Txt 5
Volts
191
Motor NP Amps
Drive Rated Amps
134
Process 1 Txt 6
Volts
192
Flux Amps Ref
0.0 Amps
135
Process 1 Txt 7
Volts
193
KP Amps
100
136
Process 1 Txt 8
Volts
194
IR Drop Volts
Based on Drive Size & Type
137
MOP Freq
Read Only
195
Slip Comp Gain
1
138
Anlg In 0 Freq
Read Only
196
KP Volts
139
Anlg In 1 Freq
Read Only
197
Prod/Cnsu Error
140
Anlg In 2 Freq
Read Only
198
Rated VT Amps
Read Only
141
Motor Mode
Read Only
199
Rated VT kW
Read Only
142
Power Mode
Read Only
200
Flux Up Time
0.0 Sec
143
Flt Motor Mode
Read Only
201
Motor OL Fault
Enabled
144
Flt Power Mode
Read Only
202
Motor OL Count
Read Only
145
Fault Frequency
Read Only
203
VT Scaling
Disabled
146
Fault Status 1
204
Ground Warning
Disabled
147
Rated Volts
Read Only
205
Latched Alarms 1
148
Rated CT Amps
Read Only
206
Alarm Mask 1
1111111111111111
149
Rated CT kW
Read Only
207
Fault Data
Read and Write
150
4-20mA Loss Sel
Min/Alarm
208
Time Data 1
151
Maximum Speed
400 Hz
209
Time Data 3
152
Encoder Type
Quadrature
210
Time Data 5
153
Motor Poles
Read Only
211
Time Data 7
154
Anlg Out 0 Offst
Disabled
212
DC Bus Memory
Read Only
155
Flying Start En
Disabled
213
PI Config
00000000
156
FStart Forward
60 Hz
214
PI Status
Read Only
157
FStart Reverse
0 Hz
215
PI Ref Select
Preset 1
158
CR1 Out Select
At Speed
216
PI Fdbk Select
Analog In 1
159
Dig Out Freq
0.00 Hz
217
PI Reference
Read Only
160
Dig Out Current
0%
218
PI Feedback
Read Only
161
Dig Out Torque
0.0 Amps
219
PI Error
Read Only
162
Torque Current
Read Only
220
PI Output
Read Only
163
Flux Current
Read Only
221
KI Process
128
164
Speed KP
0
222
KP Process
256
165
Speed KI
100
223
PI Neg Limit
-8.33% of [Maximum Freq]
166
Speed Error
Read Only
224
PI Pos Limit
+8.33% of [Maximum Freq]
167
Speed Integral
Read Only
225
PI Preload
0.00 Hz
168
Speed Adder
Read Only
226
Shear Pin Fault
Disabled
169
Boost Slope
1.5
227
Adaptive I Lim
Enabled
170
Rated Amps
Read Only
228
LLoss Restart
Track Volts
171
Rated kW
Read Only
229
Freq Ref SqRoot
Disabled
172
EEPROM Cksum
Read Only
230
Save MOP Ref
Disabled
173
Fault Alarms 1
231
Hold Level Sel
DC Hold Lvl
174
CR2 Out Select
Running
232
Current Lmt Sel