Rockwell Automation 1395 Discrete Adapter, Rev 3.XX-8.XX User Manual
Page 44

Chapter 8
Parameter Table
8-9
Parameter 451 - [A > Analog Out 1]
351 - [B > Analog Out 1]
Use: Digital Value of Analog Output 1 Signal
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: None
Description: This parameter is a Fast Sink which converts a
±
32767
digital value to a
±
10V DC output. This digital value can then be linked to
one of the drive output parameters such as Velocity Feedback, Torque
Command, Flux Command, etc. Through programming of the associated
Set-Up parameters a Scale Factor and Offset can be applied to the output
before it is converted to the analog signal.
Parameter 452 - [A > Analog Out 2]
352 - [B > Analog Out 2]
Use: Digital Value of Analog Output 2 Signal
Programming Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: None
Description: This parameter is a Fast Sink which converts a
±
32767
digital value to a
±
10V DC output. This digital value can then be linked to
one of the drive output parameters such as Velocity Feedback, Torque
Command, Flux Command, etc. Through programming of the associated
Set-Up parameters a Scale Factor and Offset can be applied to the output
before it is converted to the analog signal.
Parameter 453 - [A > Analog Out 3]
353 - [B > Analog Out 3]
Use: Digital Value of Analog Output 3 Signal
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: None
Description: This parameter is a Fast Sink which converts a
±
32767
digital value to a
±
10V DC output. This digital value can then be linked to
one of the drive output parameters such as Velocity Feedback, Torque
Command, Flux Command, etc. Through programming of the associated
Set-Up parameters a Scale Factor and Offset can be applied to the output
before it is converted to the analog signal.