What the Kits Contain
A complete installation requires one transition section and one bus bar splicing
kit. Depending on the catalog number ordered, the kit will be a left-side mount or
a right-side mount relative to the drive. Kits include all joining and splicing
hardware. An IP20, NEMA/UL Type 1 enclosure results when kits are installed
according to these instructions. If a NEMA Type 12 structure is required, follow
the CENTERLINE Motor Control Centers NEMA Type 12 Sealing
Instructions, publication
2100-IN037
.
Resource
Description
PowerFlex 750-Series AC Drives Installation Instructions,
publication
750-IN001
Provides detailed information on:
• Installation requirements
• Additional safety requirements
• Drive assembly removal and handling
• Approximate dimensions
CENTERLINE 2100 Low Voltage Motor Control Centers
Installation Instructions, publication
2100-IN012
Provides detailed information on:
• Installation requirements
• Handling instructions
• Approximate dimensions
CENTERLINE Motor Control Centers NEMA Type 12 Sealing
Instructions, publication
2100-IN037
Provides detailed information on:
• Sealing NEMA Type 12 structures
Left-side Kits
Right-side Kits
Amp
Rating
MCC Bus Bar Position
Mounting
Channel
20-750-XBUS-LHNB-1200
20-750-XBUS-RHNB-1200
1200
Standard (15 and 20 in. deep)
For use
with MCCs
that have
1.5 inch
mounting
channels.
20-750-XBUS-LHNB-2000
20-750-XBUS-RHNB-2000
2000
Standard (15 and 20 in. deep)
20-750-XBUS-LHNB-3000
20-750-XBUS-RHNB-3000
3000
Standard (15 and 20 in. deep)
20-750-XBUS-LHBB-1200
20-750-XBUS-RHBB-1200
1200
Bumped Back (20 in. deep)
20-750-XBUS-LHBB-2000
20-750-XBUS-RHBB-2000
2000
Bumped Back (20 in. deep)
20-750-XBUS-LHBB-3000
20-750-XBUS-RHBB-3000
3000
Bumped Back (20 in. deep)
20-750-XSEC-LH-20G
(1)
(1) Hardware is included to install the optional 1.5 mounting channel.
20-750-XSEC-RH-20G
(1)
N/A
20 in. deep transition section
N/A
20-750-XBUS-LLNB-1200
20-750-XBUS-RLNB-1200
1200
Standard (15 and 20 in. deep)
For use
with MCCs
that do not
have
mounting
channels.
20-750-XBUS-LLNB-2000
20-750-XBUS-RLNB-2000
2000
Standard (15 and 20 in. deep)
20-750-XBUS-LLNB-3000
20-750-XBUS-RLNB-3000
3000
Standard (15 and 20 in. deep)
20-750-XBUS-LLBB-1200
20-750-XBUS-RLBB-1200
1200
Bumped Back (20 in. deep)
20-750-XBUS-LLBB-2000
20-750-XBUS-RLBB-2000
2000
Bumped Back (20 in. deep)
20-750-XBUS-LLBB-3000
20-750-XBUS-RLBB-3000
3000
Bumped Back (20 in. deep)
20-750-XSEC-BH-15G
(2)
(2) The 15 in. deep transition section can be mounted on the left side or the right side of the PowerFlex 755 drive cabinet.
N/A
15 in. deep transition section
N/A