Original instructions indication, Safety light curtain, Muting sensor muting box – Rockwell Automation 445L Installation and Operating Instructions User Manual
Page 16

R
Muting Controller Box Installation and Operating Instructions
16
Original instructions
Indication
Safety Light Curtain
The green LED on the receiver light curtain indicates under normal operation if the protective field is uninterrupted. See corresponding
light curtain manual.
Muting Sensor
Muting Box
GuardShield Safe 4, GuardShield Safe 2
Emitter
LED = green on
Normal operation
Receiver
LED = green on
Protective field is uninterrupted
LED = red on
Protective field is interrupted.
GuardShield Micro 400
LED = green on
Protective field is uninterrupted
LED = red on
Protective field is interrupted.
LED = Flashing red
Lock out condition
LED = Flashing green
Low light intensity
Note: If the LED is flashing green, optimal alignment has not
been attained. Continue adjusting the Micro 400 until a
solid green LED is visible.
Check the sensor manual for LED indication.
The yellow LED on the RightSight sensor indicates correct
alignment of an uninterrupted beam. If the orange LED is off, the
intensity is too low and the beam should be readjusted.
Three indicators showing the condition of the muting box.
Muting lamp
off
white on
white flashing
Safety light curtain is active
Safety light curtain is muted
Muting sequence error
Output status off
green on
OSSD output = off
OSSD output = on
Error status
off
green on
Lockout
ok
POWER
Emitter
Power on
(orange)
POWER
Receiver
Power on
(orange)
Output active
(green)
Output inactive
(red)
OK
Normal operation
(green)
TEST
Test input
(red)
OptiLink
(IR light)
OptiLink
(IR light)
ATTENTION
The status output are driven from the MSR42 output info 1 and 2. The meaning of the indication can be
changed according to the configuration downloaded for the MSR42 (see Software and Optical Interface
section).