Muting Controller Box Installation and Operating Instructions
14
Original instructions
Configuration and Diagnostic Tool
Software and Optical Interface
The default configuration is set for two beam T-Type muting of a GuardShield Safe 2 or Safe 4 (445L) or a GuardShield (440L) safety light
curtain.
Other muting types can be selected with the configuration and diagnostic tool software and downloaded with the optical interface
(445L-AF6150). The software and manual are supplied with the optical interface or are available on
www.ab.com
(Product MSR42).
Table 24: Setting for the MSR42 muting controller
Table 25: Settings for the muting controller (MSR42)
Table 26: Settings for the MSR42 muting controller
Muting Type
Safety Light Curtain
Muting Sensor
Comments
2 Beam,
T-type
2 Beam,
L-type
4 Beam,
T-Type
2 Beam,
T-Type
wEnable
GS Safe
2 or Safe
4
GS
Micro
400
Guard-
Shield
(440L)
Other
Safety
Sensor
Right-
Sight
VisiSight
Other
Default
√
√
√
√
√
√
√
Default Setting
Selectable
√
√
√
√
√
√
√
√
Configurable with
MSR42 safety
software &
download with
optical interface
Selectable
√
∗
√
∗
∗
√
√
√
Selectable
√
∗
√
∗
∗
√
√
√
Inputs
Outputs
Safety
IN1
IN2
Info1
Info2
Stop delay
External Device
Monitor (EDM)
Default
Start
None
Safety Output
Lockout
No
No
Selectable
Test Input
Start EDM
Start Release
See MSR42 Safety
Software
See MSR42 Safety
Software
<120s
EDM
Start Release
Additional Settings
Time Settings
M-Lamp
Monitored
Mute Depend.
Override Active Muted Light Curtain
Light Curtain
Interrupt.
Monitored
t (sens)
t (espe)
t (mute)
t (mdo)
t (msdel)
Default
no
yes
OSSD
yes
4 s
5 s
5 min
60 s
0.05 s
Selectable
yes/no
yes/no
OSSD GuardShield
Micro 400
yes/no
See MSR42 configuration manual