beautypg.com

Rockwell Automation 20P PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board User Manual

Page 18

background image

18

PowerFlex® DC Drive - Frame A Pulse Transformer Circuit Board

Step 6: Install the New
Pulse Transformer Board
and Existing Switching
Power Supply Board

1. Install the new Pulse Transformer board and existing Switching Power

Supply board in reverse order of removal as detailed in Step 4:

Remove

the Pulse Transformer and Switching Power Supply Boards on page 6

.

2. Install the new Isolation sheet (if present) before installing the Pulse

Transformer and Switching Power Supply boards.

3. Replace the gate lead cables with the new cables provided.

4. Inspect the existing connection cables for burn marks, cracks or loose

connectors. If necessary, replace the cables connected to connector X3,
X4 (for drives with a fan) and XP on the Pulse Transformer board with
the new cables provided.

Step 7: Install the Control
EMI Shield and Control
Board

Install the Control EMI Shield and Control board in reverse order of
removal.

ATTENTION: Failure to install the Isolation sheet below the
Pulse Transformer and Switching Power Supply boards may
result in damage to the drive.

ATTENTION: Each gate lead cable must be connected to the
exact connector from which it was removed on the Pulse
Transformer circuit board or damage to the drive may occur.