Rockwell Automation 20P PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board User Manual

Page 17

background image

PowerFlex® DC Drive - Frame A Pulse Transformer Circuit Board

17

Pulse Transformer Board FIR1-XX Rev. “Q” and Higher

Set DIP switches S3 and S4, located on the Pulse Transformer board (see

Figure 1 on page 8

for location), to the correct settings based on the

appropriate table below.

Important: A blank cell below a switch in Tables E and F below indicate

that the setting is “OFF”.

Table E 230V AC Input Drives

Table F 460V AC Input Drives

Drive
Current
Rating
Code

DC
Amps

AC
Line
Amps HP

DIP Switch S3

DIP Switch S4

S3-1

S3-2

S3-3

S3-4

S3-5

S3-6

S3-7

S3-8

S4-1

S4-2

S4-3

S4-4

S4-5

S4-6

S4-7

S4-8

7P0

7

5.7

1.5

ON

ON

ON

9P0

9

7.4

2

ON

ON

ON

012

12

9.8

3

ON

ON

ON

020

20

16

5

ON

ON

ON

029

29

24

7.5

ON

ON

ON

038

38

31

10

ON

ON

055

55

45

15

ON

ON

ON

ON

073

73

60

20

ON

ON

ON

ON

093

93

76

25

ON

ON

ON

ON

110

110

90

30

ON

ON

ON

ON

Drive
Current
Rating
Code

DC
Amps

AC
Line
Amps HP

DIP Switch S3

DIP Switch S4

S3-1

S3-2

S3-3

S3-4

S3-5

S3-6

S3-7

S3-8

S4-1

S4-2

S4-3

S4-4

S4-5

S4-6

S4-7

S4-8

4P1

4.1

3.3

2

ON

ON

ON

6P0

6

4.9

3

ON

ON

ON

010

10

8.2

5

ON

ON

ON

014

14

11.4

7.5

ON

ON

ON

019

19

15.5

10 ON

ON

ON

027

27

22.1

15

ON

ON

ON

035

35

28.6

20

ON

ON

ON

045

45

36.8

25

ON

ON

ON

ON

052

52

42.5

30

ON

ON

ON

ON

073

73

59.6

40

ON

ON

ON

ON

086

86

70.3

50

ON

ON

ON

100

100

81.7

60

ON

ON

ON

ON

129

129

105.4 75

ON

ON

ON

ON