14
PowerFlex® DC Drive - Frame A Pulse Transformer Circuit Board
Sizing Resistor Configuration
below indicate the value of the designated resistor
(R1…R5) when left in place on the Pulse Transformer board, or indicate
“Remove” when the resistor should be cut off and removed from the board.
“–” in a cell in the tables below indicates that this resistor is not contained
on the Pulse Transformer board for the designated drive size.
Table A 230V AC Input Drives
Table B 460V AC Input Drives
Drive Current
Rating Code
DC
Amps
AC Line
Amps
HP
R1
R2
R3
R4
R5
7P0
7
5.7
1.5
Remove
27.4
Ω
Remove
Remove
–
9P0
9
7.4
2
Remove
Remove
39.2
Ω
Remove
–
012
12
9.8
3
Remove
27.4
Ω
Remove
Remove
–
020
20
16
5
56.2
Ω
Remove
Remove
Remove
–
029
29
24
7.5
Remove
Remove
39.2
Ω
Remove
–
038
38
31
10
Remove
27.4
Ω
Remove
Remove
–
055
55
45
15
56.2
Ω
27.4
Ω
Remove
Remove
–
073
73
60
20
Remove
27.4
Ω
39.2
Ω
Remove
–
093
93
76
25
Remove
Remove
Remove
6.98
Ω
–
110
110
90
30
Remove
Remove
Remove
6.98
Ω
–
Drive Current
Rating Code
DC
Amps
AC Line
Amps
HP
R1
R2
R3
R4
R5
4P1
4.1
3.3
2
56.2
Ω
Remove
Remove
Remove
–
6P0
6
4.9
3
Remove
Remove
39.2
Ω
Remove
–
010
10
8.2
5
Remove
Remove
39.2
Ω
Remove
–
014
14
11.4
7.5
Remove
27.4
Ω
Remove
Remove
–
019
19
15.5
10
56.2
Ω
Remove
Remove
Remove
–
027
27
22.1
15
Remove
Remove
39.2
Ω
Remove
–
035
35
28.6
20
Remove
27.4
Ω
Remove
Remove
–
045
45
36.8
25
56.2
Ω
Remove
39.2
Ω
Remove
–
052
52
42.5
30
56.2
Ω
27.4
Ω
Remove
Remove
–
073
73
59.6
40
Remove
27.4
Ω
39.2
Ω
Remove
–
086
86
70.3
50
Remove
Remove
Remove
6.98
Ω
–
100
100
81.7
60
Remove
Remove
Remove
6.98
Ω
–
129
129
105.4
75
Remove
Remove
Remove
6.98
Ω
–