beautypg.com

Table c, Table d, In the – Rockwell Automation 20P PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board User Manual

Page 16: Total resistance values

background image

16

PowerFlex® DC Drive - Frame A Pulse Transformer Circuit Board

Total Resistance Values

Table C 230V AC Input Drives

Table D 460V AC Input Drives

3. Seal the TA potentiometer using RV (silicon).

Continue with Step 6:

Install the New Pulse Transformer Board and

Existing Switching Power Supply Board on page 18

.

Drive Current
Rating Code

DC
Amps

AC Line
Amps

HP

Set RTA Value Using

TA Potentiometer

(Ohms)

7P0

7

5.7

1.5

34.971

9P0

9

7.4

2

45.333

012

12

9.8

3

34

020

20

16

5

61.2

029

29

24

7.5

42.207

038

38

31

10

32.211

055

55

45

15

22.255

073

73

60

20

16.767

093

93

76

25

13.161

110

110

90

30

11.127

Drive Current
Rating Code

DC
Amps

AC Line
Amps

HP

Set RTA Value Using

TA Potentiometer

(Ohms)

4P1

4.1

3.3

2

59.707

6P0

6

4.9

3

40.8

010

10

8.2

5

40.8

014

14

11.4

7.5

29.143

019

19

15.5

10

64.421

027

27

22.1

15

45.333

035

35

28.6

20

34.971

045

45

36.8

25

27.2

052

52

42.5

30

23.538

073

73

59.6

40

16.767

086

86

70.3

50

14.233

100

100

81.7

60

12.24

129

129

105.4

75

9.488