03-000050 rev A

Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 Pg. 19

FlatPAC-EN/EN MI Design Guide

2 VI-J00 modules only.

O

UTPUT

(

CONT

D

.)

Maxi/Mini/Micro Modules

Parameter

MIN.

TYP.

MAX.

UNITS

NOTES

Setpoint Accuracy*

±0.5

±1

% of V

NOM

Load Regulation

±0.01

% of V

NOM

See module design guide for e

exact specifications.

Temperature Regulation

0.002

0.005

%/°C

-20 to 100°C

Long Term Drift

0.02

%/K hours

Output Ripple and noise:

Maxi

75

mV p-p

See module design guide

Mini

100

mV p-p

for exact output ripple

Micro

125

mV p-p

specifications.

Voltage Trim Range

Maxi/Mini/Micro Slots

10-110

% Vout

Preload may be required.

Total Remote Sense Compensation

0.5

Volts

Autosense. See pg 14

OVP Set Point

112

135

% of V

out

Recycle power

Current Limit

102

115

135

% of I max

Auto Recovery

Overtemperature Limiting

Not available

* For special, adjustable voltages and 48Vdc outputs, maximum setpoint accuracy is 2% of Vnom.
Note: See individual module datasheets for specific module specifications.

E

NVIRONMENTAL

Storage Temperature

-40°C to +100°C

Operating Temperature

Ambient air (see derating curves)

-20°C to +70°C (MI -40°C to +70°C)

Case Temperature

-20°C to +90°C (MI -40°C to +90°C)
(75° for full size VI-200 module)

Specific temperature data on all module configurations can be obtained by contacting Applications Engineering.

Altitude

Derate 2.6% total output power for each 1,000 ft to a maximum
operating altitude of 15,000 ft. Non-operating storage maximum
altitude is 40K.

Humidity

0 to 95% non condensing

Product Weight

3.4 lbs. (1,5 kg)

Dimensions

1.4" H (35,6mm) x 5.0" W (127,0mm) x 9.20" L (233,7mm)

Warranty**

2 years limited warranty. See vicorpower.com for complete warranty
statement.

** Opening, repairing or modifying the unit will void the warranty. If you have any problem with the power supply, please
contact Customer Service at 1-800-735-6200. If the unit needs to be returned for inspection/analysis, an RMA number will
be issued. All units must have a RMA number prior to return.

This manual is related to the following products: