Vicor FlatPAC-EN MI EN Compliant Autoranging Switchers User Manual
Page 19

03-000050 rev A
Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 Pg. 19
FlatPAC-EN/EN MI Design Guide
2 VI-J00 modules only.
O
UTPUT
(
CONT
’
D
.)
Maxi/Mini/Micro Modules
Parameter
MIN.
TYP.
MAX.
UNITS
NOTES
Setpoint Accuracy*
±0.5
±1
% of V
NOM
Load Regulation
±0.01
% of V
NOM
See module design guide for e
exact specifications.
Temperature Regulation
0.002
0.005
%/°C
-20 to 100°C
Long Term Drift
0.02
%/K hours
Output Ripple and noise:
Maxi
75
mV p-p
See module design guide
Mini
100
mV p-p
for exact output ripple
Micro
125
mV p-p
specifications.
Voltage Trim Range
Maxi/Mini/Micro Slots
10-110
% Vout
Preload may be required.
Total Remote Sense Compensation
0.5
Volts
Autosense. See pg 14
OVP Set Point
112
135
% of V
out
Recycle power
Current Limit
102
115
135
% of I max
Auto Recovery
Overtemperature Limiting
Not available
* For special, adjustable voltages and 48Vdc outputs, maximum setpoint accuracy is 2% of Vnom.
Note: See individual module datasheets for specific module specifications.
E
NVIRONMENTAL
Storage Temperature
-40°C to +100°C
Operating Temperature
Ambient air (see derating curves)
-20°C to +70°C (MI -40°C to +70°C)
Case Temperature
-20°C to +90°C (MI -40°C to +90°C)
(75° for full size VI-200 module)
Specific temperature data on all module configurations can be obtained by contacting Applications Engineering.
Altitude
Derate 2.6% total output power for each 1,000 ft to a maximum
operating altitude of 15,000 ft. Non-operating storage maximum
altitude is 40K.
Humidity
0 to 95% non condensing
Product Weight
3.4 lbs. (1,5 kg)
Dimensions
1.4" H (35,6mm) x 5.0" W (127,0mm) x 9.20" L (233,7mm)
Warranty**
2 years limited warranty. See vicorpower.com for complete warranty
statement.
** Opening, repairing or modifying the unit will void the warranty. If you have any problem with the power supply, please
contact Customer Service at 1-800-735-6200. If the unit needs to be returned for inspection/analysis, an RMA number will
be issued. All units must have a RMA number prior to return.