beautypg.com

Specifications – Vicor FlatPAC-EN MI EN Compliant Autoranging Switchers User Manual

Page 18

background image

Consult Applications Engineering when trimming outputs below 5V.

Specifications

(Typical at 25°C, nominal line and 75% load, unless otherwise specified)

G

ENERAL

Number of Outputs

1-4

Modules

VI-200/VI-J00, VE-200/VE-J00: Maxi/Mini/Micro

Efficiency

Typically > 70%

Safety Agency Approvals

cURus – UL 60950-1, CSA 60950-1
cTUVus – EN 60950-1, UL 60950-1, CSA 60950-1
CE Mark – Low Voltage Directive, 73/23/EEC amended by 93/68/EEC

Vibration

Mil-STD 810 Minimum Integrity (MI chassis only)

Shock

Mil-STD 810 40G Functional Shock (MI chassis only)

Maximum Output Power

Up to 500 Watts; 425 Watts for EN 61000-3-2/A14 compliance

(not to exceed input current of 9A)

(105/190 Vac minimum input)

I

NPUT

Input

90-132/180-264 Vac 47-63Hz
250-380 Vdc

Inrush Current

8.5A peak @ 115 Vac and 17A peak at 230 Vac

Line/Load Regulation

VI200/VI-J00:± 0.2% max.10% to full load; ± 0.5% max. No load to 10% load

Line Regulation*

Maxi/Mini/Micro:± 0.20% max. to 0.3% max LL to HL, Full Load

Ride Through Time

500W

400W

@ 115Vac (typical)

12ms

15ms

@ 230Vac (typical)

16ms

18ms

Harmonic Distortion

EN61000-3-2 A/14 (For output power

≤ 425W or input current not

in excess of 3.33 A rms at 230 Vac, 50 Hz.)

Conducted EMI

FCC and EN 55022 Class A

(certain configurations meet EN 55022 Class B)

Mil-STD 461 may require external filter - contact factory

Power Factor

>.70

Transient Burst Immunity

EN61000-4-4

Surge Immunity

EN61000-4-5

Voltage Dips

EN61000-4-11

Dielectric Withstand

Primary to Chassis GND = 1,500 V

RMS

Primary to Secondary = 3,000 V

RMS

Secondary to Chassis GND = 500 V

RMS

* See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of normal output voltage.

O

UTPUT

VI-200/VI-J00 Modules

Parameter

MIN.

TYP.

MAX.

UNITS

NOTES

Setpoint Accuracy*

0.5

1

%

of Vnom

Load/line Regulation

±0.2

%

10% to Full Load

Load/line Regulation

±0.5

%

Load to 10%

Temperature Regulation

0.01

0.02

%/°C

Over rated temp.

Long Term Drift

0.02

%/K hours

Output Ripple & Noise:

VI/E-200

100

mV p-p

See module design guide

VI/E-J00

100

mV p-p

for exact specifications

Voltage Trim Range

VI-200/VI-J00 Slots

50-110

% V out

± 10% on 10-15 Vout

Total Remote Sense Compensation

0.5

Volts

Autosense. See pg.14

OVP Set Point

1

115

125

135

%Vout

Recycle Power

Current Limit

105

115

125

% of I max

Auto Recovery

Short Circuit Current

20 (105

2

)

130

%

Overtemperature Limiting

Not available on VI-J00

* For special and adjustable voltages, maximum setpoint accuracy is 2% of Vnom.
1 131% Nominal for Booster Modules. No OVP for VI-J00

Pg 18

Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474

03-000050 rev A

FlatPAC-EN/EN MI Design Guide

This manual is related to the following products: