FlatPAC-EN/EN MI Mechanical Drawings
Pg 10
Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474
03-000050 rev A
FlatPAC-EN/EN MI Design Guide
1
CB J1 (12 PIN)
MBJ1
1
9.53
.38
215.90
8.500
12.70
.50
101.60
4.000
4X #8-32 x .125 OR M4 x 3mm MAX LG
FROM OUTSIDE OF POWER SUPPLY
CUSTOMER MOUNTING HOLES
138.43
5.450
147.96
5.825
5.56
.219
115.89
4.563
AIR
FLOW
CUSTOMER MOUNTING HOLES
4X #8-32 x .250 OR M4 x 6mm MAX LG
FROM OUTSIDE OF POWER SUPPLY
OUTPUTS M1 & M2
OUTPUTS M3 & M4
J2
J3
OUTPUT M2 & M3
OUTPUT M1
J2
J3
OUTPUT M1
OUTPUT M2
+
M2
J2
-
M2
M1
M1
-
J1
+
PIN 1
N/C
N/C
L1
L2/N
GND
0.77
.03
35.59
1.40
233.69
9.20
C1
C2
MATING CONNECTOR:
HOUSING: MOLEX (50-57-9412)
SOCKET CRIMP 24-30 AWG: MOLEX (16-02-0097)
CRIMP TOOL: MOLEX (11-01-0209)
2
3
CBJ1 E/D INTERFACE CONNECTOR
4
PIN REF
DESCRIPTION
CBJ1-1 SGND
SIGNAL GROUND
CBJ1-2 N/C
N/C
CBJ1-3 ACOK
AC POWER OK
CBJ1-4 TX
TRANSMIT
CBJ1- 5 RX
RECEIVE
CBJ1-6 E/D-4
ENABLE/DISABLE
CBJ1-7 E/D-3
ENABLE/DISABLE
CBJ1- 8 E/D-2
ENABLE/DISABLE
CBJ1-9 E/D-1
ENABLE/DISABLE
CBJ1-10 GSD
GENERAL SHUTDOWN
CBJ1-11 N/C
N/C
CBJ1-12 +5VS
+5V@300mA
3
2
1
REFERENCE
DESIGNATION
NOTES: UNLESS OTHERWISE SPECIFIED
MB MOTHER
BOARD
CB CONTROL
BOARD
CONNECTOR PART NUMBERS SPECIFIED ARE MOLEX OR EQUIVALENT
A COMPLETE SET OF MATING CONNECTORS CAN BE PURCHASED FROM WESTCOR BY SPECIFYING
CONNECTOR KIT P/N 19-130044.
4
CBJ4 AND CBJ5 ARE PART OF THE RS-232 MICROCONTROLLER FUNCTIONS. SEE PAGE 12 INFORMATION.
5
FOR A VICOR 2 UP FLATPAC RETROFIT, USE MOUNTING HOLES C1 AND C2. SEE PAGE 4 OR 7 FOR MOUNTING DETAILS.
5
5
MATING CONNECTOR:
HOUSING: MOLEX (39-01-4051)
SOCKET CRIMP 16 AWG: MOLEX (39-00-0090)
CRIMP TOOL: MOLEX (11-01-0199)
MBJ1 A/C INPUT
2
3
Measurement tolerances are
Fractions
+/-
1/32
Decimals
.xx +/- .01
.xxx +/- .005
Angles
+/-
1/2
o
Note: The type of output connector a FlatPAC-EN has
depends on which modules are used.
See page 11 for detailed