Installation, Before you start, Important message save these instructions – Regency Energy E18 Small Gas Insert User Manual
Page 7: General safety information

Regency
®
E18 Gas Fireplace Insert
7
INSTALLATION
BEFORE YOU START
Safe installation and operation of this appliance 
requires common sense, however, we are required 
by the Canadian Safety Standards and ANSI 
Standards to make you aware of the following:
CLOTHING OR OTHER FLAMMABLE 
MATERIAL SHOULD NOT BE PLACED 
ON OR NEAR THE APPLIANCE.
CHILDREN AND ADULTS SHOULD BE 
ALERTED TO THE HAZARDS OF HIGH 
SURFACE TEMPERATURES, ESPE-
CIALLY THE FIREPLACE GLASS, AND 
SHOULD STAY AWAY TO AVOID BURNS 
OR CLOTHING IGNITION. 
INSTALLATION AND REPAIR SHOULD 
B E D O N E B Y A N AU T H O R I Z E D 
SERVICE PERSON. THE APPLIANCE 
SHOULD BE INSPECTED BEFORE 
USE AND AT LEAST ANNUALLY BY A 
PROFESSIONAL SERVICE PERSON. 
MORE FREQUENT CLEANING MAY 
BE REQUIRED DUE TO EXCESSIVE 
LINT FROM CARPETING, BEDDING 
MATERIAL, ETC. IT IS IMPERATIVE THAT 
CONTROL COMPARTMENTS, BURNERS 
AND CIRCULATING AIR PASSAGEWAYS 
OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE 
APPLIANCE SHOULD BE LOCATED 
OUT OF TRAFFIC AND AWAY FROM 
FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS 
APPLIANCE CORRECTLY WILL VOID 
YOUR WARRANTY AND MAY CAUSE A 
SERIOUS HOUSE FIRE.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE 
IN THE SAME AREA AS THE APPLI-
ANCE. TODDLERS, YOUNG CHILDREN 
AND OTHERS MAY BE SUSCEPTIBLE 
TO ACCIDENTAL CONTACT BURNS. A 
PHYSICAL BARRIERS IS RECOMMEND-
ED IF THERE ARE AT RISK INDIVIDUAL 
IN THE HOUSE. TO RESTRICT ACCESS 
TO A FIREPLACE OR STOVE, INSTALL 
AN ADJUSTABLE SAFETY GATE TO 
KEEP TODDLERS, YOUNG CHILDREN 
AND OTHER AT RISK INDIVIDUALS OUT 
OF THE ROOM AND AWAY FROM HOT 
SURFACES. 
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The Regency
®
Gas Fireplace must be installed in
accordance with these instructions. Carefully read 
all the instructions in this manual fi rst. Consult the 
"authority having jurisdiction" to determine the need 
for a permit prior to starting the installation. It is the 
responsibility of the installer to ensure this fi replace 
is installed in compliance with the manufacturer's 
instructions and all applicable codes.
GENERAL SAFETY
INFORMATION
The condition of the appliance, that the E18 is 
to be installed into, shall be in accordance with 
reasonable concepts of safety, substantiality and 
durability. Component parts shall be well fi tted and 
not show signs of becoming warped, bent, broken 
or otherwise damaged during the installation. Every 
part of the appliance shall be secured against 
displacement and constructed to maintain a fi xed 
relationship between essential parts under normal 
and reasonable conditions of handling and usage.
1. The appliance installation must conform with
local codes or, in the absence of local codes, 
with the current Canadian or National Gas 
Codes, CAN1-B149 or ANSI Z223.1 Installation 
Codes.
2. The appliance when installed, must be electri-
cally grounded in accordance with local codes, 
or in the absence of local codes with the current 
National Electrical Code, ANSI/NFPA 70 or CSA 
C22.1 Canadian Electrical Code.
3. See general construction and assembly in-
structions. The appliance and vent should be 
enclosed.
4. This appliance must be connected to the speci-
fi ed vent and termination cap to the outside of 
the building envelope. Never vent to another 
room or inside a building. Make sure that the 
vent is installed as per Venting instructions.
5. This appliance may only be installed in a vented,
solid fuel burning masonry, in any of the ap-
proved zero clearance gas appliances listed in 
this manual, or as a zero clearance appliance 
with the zero clearance kit. 
6. This appliance is Listed for bedroom installations
when used with a Listed Millivolt Thermostat.
Outside combustion air supply is also required. 
Some areas may have further requirements, 
check local codes before installation.
Emissions from burning wood or gas could 
contain chemicals known to the State of 
California to cause cancer, birth defects or 
other reproductive harm.
7. This appliance is Listed for Alcove installations,
maintain minimum Alcove clearances as follows, 
minimum ceiling height of 37-7/8" from the top 
of the glass door, minimum width of 49" and a 
maximum depth of 29".
8. Inspect the venting system annually for blockage
and any signs of deterioration.
9. Any safety glass removed for servicing must be
replaced prior to operating the appliance.
10. To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fi replace 
insert.
11. Wear gloves and safety glasses for protection
while doing required maintenance.
12. Ensure adequate combustion and ventilation air.
13. Under no circumstances should this appliance
be modifi ed. Parts that have to be removed for 
servicing should be replaced prior to operating 
this appliance.
14. Installation and any repairs to this appliance
should be done by a qualifi ed service person. A 
professional service person should be called to 
inspect this appliance annually. Make it a practice 
to have all of your gas appliances checked 
annually.
15. Do not slam shut or strike the glass door.
16. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in 
this appliance.
17. The appliance area must be kept clear and free
of combustible materials, (gases and other fl am-
mable vapours and liquids).
18. Do not use this appliance if any part has been
under water. Immediately call a qualifi ed service 
technician to inspect the appliance and to replace 
any part of the electrical control system and any 
gas control which has been under water.
19.
WARNING: Failure to position the parts 
in accordance with the diagrams in 
this manual or failure to use only parts 
specifi cally approved with this appliance 
may result in property damage or 
personal injury.
20.
WARNING: Operation of this appliance 
when not connected to a properly 
installed and maintained venting system 
or tampering with the blocked vent shut-
off system can result in carbon monoxide 
(CO) poisoning and possible death.