INSTALLATION

MODIFICATION OF MONTIGO EP28-2, EP28-4

OR EP28-5

*Units could have any of the following Log Sets Installed: 2LB (2 Log Set),
MB (2 Log Set), 4LB (4 Log Set)

1. Turn off unit, disconnect Gas and Power.

2. Remove Upper and Lower Louvers.

3. Remove Optional Doors or Screen Mesh.

4. Remove Logs.

5. Remove Bottom Door Rail (See Diagram 5.1).

6. Remove Burner Assembly (See Diagram 5.1).

Diagram 5.1

Diagram 5.2

Grind corners

Diagram 5.3

Diagram 5.4

Modidfi ed edges must be fl ush to allow proper seating of the E18

outer shell.

7. Cut the Front Bar Out on the left and right Sides of the Firebox. (See

Diagram 5.2). Grind the corners smooth on the left side - to reduce the
risk of wires being cut. Alternate method is to cut front bar in the center
and break off each side spot weld completely.

8. Remove Hood and Inner Baffl e (See Diagram 5.3).

9. Bend Down the Three Flanges at the Bottom of the Firebox or cut them

off (See Diagram 5.4).