Installation, E18 install specifi cations – Regency Energy E18 Small Gas Insert User Manual
Page 33
Regency
®
E18 Gas Fireplace Insert
33
INSTALLATION
5 1/4"
133mm
8 3/16"
208mm
2 1/8"
54mm
C
Firesong 220N Firebox
E18 Insert
Leg heig
Leg Setting / Outer Shell Position
5 - 3/16"
[132mm]
PP
'
(,QVHUW
)LUHVRQJ1)LUHER[
9HQWVRQFHQWHU
'(7$,/'
6&$/(
$GDSWRU3ODWH
)DVWHQHU6HWWLQ
PP
/HJ6HWWLQJ2XWHU6KHOO3RVLWLRQ
)OH[$GDSWRU/HQJWK
&ROODU3ODWH6HWWLQJ9HQWSRVLWLRQ
E18 Install Specifi cations
See Installtion of E18 into Existing Units for General Installation Guidance.
This install of the E18 uses Vent Connection Type A..
The Length of 4" Flex needed is 1-15/16" semi-expanded. Secure fl ue adapter top plate to under side of existing fi rebox using 4 self tap-
ing screws.
1. Loosen 2 x philips screws on both right and left legs.
2. See above diagram below for required leg setting.
3. Install with supplied phillips screws to prepunched holes and tighten previ-
ous screws that were loosened in Step 1.
4. Keep left side leg loose until outer fi rebox is in position in ZC box - to allow
adjustment of gas line.
Firesong 22N faceplate is an outside fi t, if the front metal face
of the 220N is covered with stone or tile - a custom faceplate
will be required.
The following measurements of the 220N metal face will be
visible if no stone or tile is covering it. If this metal face is vis-
ible, the standard Faceplate (6161-920) will fi t.
Set to this
hole
Set to this
hole
Right side shown
Secure top plate to fi rebox w/4 screws.
Secure vent slide plate to fl ex pipe with 4
screws
3"
(76mm)
3"
(76mm)
1"
(25mm)
Firesong 220N
Front Facing measurements
Note: this measurement
is above lower area