Parameter Options Default
Description
Channel
No, Ch1-Ch6
None
Defines a measurement channel for multi-
meter energy metering. Not used for a
single self-metering channel if there are no
external sources. Set to Ch1 for internal
energy sources, and to Ch2 through Ch6 for
external sources in the event of multi-
channel energy metering.
Register Source List
Source
Input
None
kWh IMPORT
KWh EXPORT
kvarh IMPORT
kvarh EXPORT
kvarh Q1
kvarh Q2
kvarh Q3
kvarh Q4
kVAh TOTAL
kVAh IMPORT
kVAh EXPORT
DI1-DI8
None
Links an internal or external energy source
to the billing register.
Multiplier
0.001 to 100.000
1.000
The multiplication factor for the energy
source. Not effective for internal sources.
Target
Reg#1- Reg#10
None
Defines the target billing register for the
energy source. It is set automatically.