Ordering information, 8 9 x x n - x - x x, Iconverter – Omnitron Systems Technology iConverter GX/TM2 User Manual
Page 4: Gx/tm2
ORDERING INFORMATION
Page 4
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • [email protected] • 38 Tesla, Irvine, CA 92618
iConverter
GX/TM2
© 2014 Omnitron Systems Technology, Inc. All rights reserved.
iConverter
and
NetOutlook
are Registered Trademarks of Omnitron Systems Technology,
Inc. Trademarks are owned by their respective companies. Specifications are subject to change without notice.
091-8920N-001E 4/14
Fiber
Type
Distance
Connector Type
Tx
Lambda
(nm)
Rx
Lambda
(nm)
Min. Tx
Power
(dBm)
Max. Tx
Power
(dBm)
Min. Rx
Power
(dBm)
Max. Rx
Power
(dBm)
Min.
Attenuation
(dB)
Link
Budget
(dB)
ST
SC
LC
SFP
-
-
-
-
-
8939N-0
-
-
-
-
-
-
-
-
MM/DF
220 / 550m
1
8920N-0 8922N-0 8926N-0
-
850
850
-10
-4
-17
-3
-
7
MM/DF
2km
-
8922N-6
-
-
1310
1310
-9.5
-3
-19.5
-3
-
10
SM/DF
12km
8921N-1 8923N-1 8927N-1
-
1310
1310
-9.5
-3
-19.5
-3
-
10
SM/DF
34km
-
8923N-2 8927N-2
-
1310
1310
-5
0
-23
-3
3
18
SM/DF
80km
-
8923N-3 8927N-3
-
1550
1550
-5
0
-23
-3
3
18
SM/DF
110km
-
8923N-4 8927N-4
-
1550
1550
0
5
-24
-3
8
24
SM/DF
140km
-
8923N-5 8927N-5
-
1550
1550
2
5
-28
-8
13
30
SM/SF
2
20km
-
8930N-1
-
-
1310
1550
-9.5
-3
-20
-3
-
10.5
SM/SF
2
20km
-
8931N-1
-
-
1550
1310
-9.5
-3
-20
-3
-
10.5
SM/SF
2
40km
-
8930N-2
-
-
1310
1550
-3
0
-20
-3
3
17
SM/SF
2
40km
-
8931N-2
-
-
1550
1310
-3
0
-20
-3
3
17
SM/SF
2
20km
-
8932N-1
-
-
1310
1490
-9
-3
-21
-3
-
12
SM/SF
2
20km
-
8933N-1
-
-
1490
1310
-9
-3
-21
-3
-
12
For wide temperature (-40 to 60
o
C), add a “W” to the end of the model number. For extended temperature (-40 to 75
o
C), add a “Z” to the end of the model number.
Contact Omnitron for other fiber options.
1
62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm multimode fiber up to 550m. Refer to the fiber cable manufacturer for multimode distance specifications.
2
Single-fiber (SF) media converter are used in pairs. The Tx wavelength on one end has to match the Rx wavelength on the other.
Order the appropriate SFPs separately. Visit
8 9 x x N - x - x x
Standard Operating Temperature Range
W
Wide Operating Temperature Range
Z
Extended Operating Temperature Range
Plug-in Module
A
Standalone with External US AC Power Supply
B
Standalone with External Universal AC Power Supply
C
Standalone with DC Terminal Power
D
Standalone with integrated mounting brackets and External US AC Power Supply
E
Standalone with integrated mounting brackets and External Universal AC Power Supply
F
Standalone with integrated mounting brackets and DC Terminal Power